EVO FRONT LOADING DISHWASHER
temperature which will guarantee correct hygienisation in accordance with health regulations.
If the water input temperature is lower than 40 ⁰C / 104 ⁰F, the times required to reach the operating
temperatures will increase and productivity levels will decrease. The thermo-stop function may extend
In models fitted with this function, the wash cycle may be extended by up to a maximum of 8 minutes, at which
point the rinse cycle will start regardless of the rinse temperature.
Models CONCEPT PLUS also have the EFFI-RINSE SYSTEM, which ensures a correct hygienisation temperature at
all times and a constant rinse pressure.
When the machine is switched on, it is possible to configure the “Thermostop”.
When the machine is in position 0, with the START button pressed, if the encoder is turned to P1, the “Thermostop”,
is enabled, and the L2 Led lights up for 5 seconds to show that it has been activated.
When the machine is in position 0, with the START button pressed, if the encoder is turned to drain, the
“Thermostop”, is disabled, and the LMP Led lights up for 5 seconds to show that it has been deactivated.
By default, the “Thermostop” will be enabled or disabled depending on the status of DIP4:
• If DIP4=0: “Termostop” disabled.
• If DIP4=1: “Termostop” enabled.
If the user configures it as enabled or disabled, this configuration is observed and the dip switches are ignored.
9.5.2. SWITCHING ON THE MACHINE
When the machine is switched on, i.e. it is not in position 0 and it is a machine without regeneration (DIP2=0), the
RG output will always be active.
In addition, when the machine is running, the L1 led (machine on) and the L3 led (machine active) are always lit
regardless of the DIP2.
9.5.3. FILLING
If the machine is not at the “0” position, the fill cycle will start, provided it is not already full.
9.5.4. FILLING DISHWASHER WITHOUT AIR BREAK
In dishwashers without Air Break, if the door is closed (IP=1) and the tank is not full (PT=1), the output V is
activated until the tank is full. The water enters the boiler and fills the tank thanks to the mains pressure.
When the sensor detects that the tank has reached the required temperature, the Machine Ready LED (LMP) lights
up.
9.5.5. FILLING DISHWASHER WITH AIR BREAK
However, in dishwashers with Air Break, the boiler is filled through the Vreg outlet (until PC=0), the water is heated
and the tank is filled using the rinse pump (V=1) for 15 seconds provided the door is closed (IP=1).
While the tank is filling, at the same time water is loaded into the boiler.