9
FOR USER
3.TECHNICAL SPECIFICATION
Model
IPHC150T
IPHC300T
Advised pool volume (m
3
)
130~260
260~520
Operating air temperature ()
-7~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)
60.0
110.0
COP at 50% capacity
10.1
10.0
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)
40.0
81.0
COP at 50% capacity
6.8
6.8
Performance Condition: Air 35,Water 28, Humidity 80%
Cooling capacity (kW)
26.5
54.0
Compressor
DC inverter
Heat exchanger
Spiral titanium tube in PVC
Casing
Aluminum-alloy
Fan direction
Vertical
Power supply
400V/3 Ph/50Hz
Rated input power at air 15°C (kW)
2.25~8.89
4.69~17.6
Rated input current at air 15°C (A)
3.25~12.8
6.77~25.4
Max input current (A)
20.0
40.0
Circuit breaker (A)
25.0
48.0
Advised water flux (m³/h)
20~25
40~50
Water pipe in-out size (mm)
75
110