12
FOR INSTALLERS AND PROFESSIONALS
2. INSTALLATION AND MAINTENANCE
The heat pump must be installed by a professional team. The users are not qualified to install by
themselves, otherwise the heat pump might be damaged and risky for users’ safety.
2.1. Notice before installation
2.1.1. The inlet and outlet water unions can’t bear the weight of soft pipes. The heat pump must be
connected with hard pipes!
2.1.2In order to guarantee the heating efficiency, the water pipe length should be ≤10m between
the pool and the heat pump.
2.2. Installation instruction
2.2.1. Location and size
The heat pump should be installed in a place with good ventilation
* MINIMUM DISTANCE
Filter
Water processor
Water switch