3-6
FAY-002
Segment 1~5 Speed (PWM)
Input fan speed in PWM duty-cycle. Input value range: [0~100]
The following item replaces Segment 1~5 Speed (PWM) when Chassis Smart
Fan Control is set to [Auto by RPM].
Segment 1~5 Speed (%)
Input fan speed percentage. Input value range: [0~100]
Full Speed Count [3000]
Input fan full speed count value. Input value range: [500~15000]
Full Speed Count is only available when Chassis Smart Fan Control is set to
[Auto by RPM].
Manual Setting [3000]
Specify xed RPM. Input value range: [500~15000]
Manual Setting is the only item available when Chassis Smart Fan Control is
set to [Manual by RPM].
Manual Setting [100]
Specify xed Duty-Cycle. Input value range: [0~100]
Manual Setting is the only item available when Chassis Smart Fan Control is
set to [Manual by Duty-Cycle].
3.3.8 IDE Configuration
Serial-ATA (SATA) [Enabled]
Allows you to enable or disable Serial-ATA. Conguration options: [Enabled]
[Disabled]
SATA Mode [AHCI Mode]
Allows you to set the SATA conguration.
[AHCI Mode] Set to [AHCI] when you want the SATA hard disk drives to
use AHCI (Advanced Host Controller Interface). AHCI allows
the onboard storage driver to enable advanced Serial ATA
features that increases storage performance on random
workloads by allowing the drive to internally optimize the order
of commands.
[IDE Mode] Set to [IDE] when you want to use the Serial ATA hard disk
drives as Parallel ATA physical storage devices.