Pump Assembly Continued
LITTLE OR
NO MOVEMENT
LITTLE OR
NO MOVEMENT
LITTLE OR
NO MOVEMENT
LITTLE OR
NO MOVEMENT
9. Inspect the exible coupling radial and axial
t. It should have little or no movement and
be slightly more loose than the motor shaft
t. It should also slide smoothly on and o
the pump shaft.
10. Once proper exible coupling t on both
shafts has been obtained, remove the ex-
ible coupling and proceed with Initial Pump
Alignment.
NOTES: The exible coupling will not be need-
ed until the Final Pump Alignment procedure.
Figure 27 - Check Flex Coupling Fit