REFRIGERATION AND ELECTRICAL DATA
BEFORE 01/01/2020
Model RSSM360SC RSSM360R
RSSD360SC RSSD360R
RSSM378SC RSSM378R
RSSD378SC RSSD378R
ELECTRICAL
Power Supply, Volts 120/208-240Volts 120Volts
Frequency 60 Hertz 60 Hertz
Phase 1 Phase 1 Phase
Number of Wires 3 + ground 2 + ground
AMPS VOLTS AMPS VOLTS
Compressor
RLA 4.3 208-240 ---- ----
LRA 31.0 208-240 ---- ----
Condenser Fan Motor 0.6 208-240 ---- ----
Evaporator Fan Motor 0.4 120 0.4 120
Lights 1.0 120 1.0 120
(Includes Optional Shelf Lights)
Condensate Pan Heater 5.0 240 ---- ----
Condensate Pump 0.5 240 1.0 120
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit Ampacity.
REFRIGERATION
Self-Contained Models
Before 01/01/2020 Refrigeration R404A Charge Self Contained
The self-contained models are shipped from the factory with a completely operational R404A
refrigeration system and require no modifications or adjustments upon installation. Case must be
installed as per the installation section of this manual to provide proper condensing air cooling.
Self-Contained Refrigeration Operation
The unit temperature is controlled by the Electronic control and timers outlined in the control section
of this manual.
Note: The condenser fan runs continuously.
Remote Models
Refrigerant & BTU Requirements
Refrigerant R404A Before 01/01/18
5400 BTU’S @20°F Evap/90° Ambient
Refrigerant R449a After 01/01/18
5400 BTU’S @20°F Evap/90° Ambient
Refrigerated Self-Serve Merchandiser (High Profile) Page 31A