REFRIGERATION AND ELECTRICAL DATA
AFTER 01/01/2020
Model RSSM360SC-6 RSSM360R-6
RSSD360SC-6 RSSD360R-6
RSSM378SC-6 RSSM378R-6
RSSD378SC-6 RSSD378-R
ELECTRICAL
Power Supply, Volts 208-240Volts 208-240Volts
Frequency 60 Hertz 60 Hertz
Phase 1 Phase 1 Phase
Number of Wires 2 + ground 2 + ground
AMPS VOLTS AMPS VOLTS
Compressor
RLA 4.3 208-240 ---- ----
LRA 31.0 208-240 ---- ----
Condenser Fan Motor 0.6 208-240 ---- ----
Evaporator Fan Motor 0.4 208-240 0.4 208-240
Lights 1.0 208-240 1.0 208-240
(Includes Optional Shelf Lights)
Condensate Pan Heater 5.0 208-240 ---- ----
Condensate Pump 0.5 208-24 0.5 208-240
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit Ampacity.
REFRIGERATION
Self-Contained Models
The self-contained models are shipped from the factory with a completely operational R449a
refrigeration system and require no modifications or adjustments upon installation. Case must be
installed as per the installation section of this manual to provide proper condensing air cooling.
Self-Contained Refrigeration Operation
The unit temperature is controlled by the Electronic control and timers outlined in the control section
of this manual.
Note: The condenser fan runs continuously.
Remote Models
Refrigerant & BTU Requirements