DOOR FORCED ALARM: An alarm will trigger if an abnormal way to open the door has been
detected, for example because there has not been any previous open the door” command.
EXTERNAL RELEASE: Only available in panel programmed as PANEL 1. It activates or
deactivates the additional relay performance.
A module Ref. 1491 (4 relay module) must be connected to the RS485 port of the panel No.1.
See INSTALLATION section for further details.
o 1-4 DOOR RELAY TIME: Time that the corresponding additional door relay keeps
active (1-9s optional).
o 1-4 OPEN DOOR DELAY: The time that the open-door command has be sent and the
relay is not activated. The relay will active after the DOOR DELAY TIME be set. Open
door relay is useful when the door is not close the panel. (option 0-9 s).
ADMIN CARD: Admin/master card ID registered to enrol additional prox cards. This option is
useful when there is not MEET MAGEMENT SOFTWARE available.
When there is no management software, enter 0000 if you do not know the ID of the admin
card. The first MIFARE prox card detected by the reader will act as admin/master card.
The card of the residents can be added afterwards.
To program user cards, present the admin/master card previously created on the card reader.
The panel will enter in cards program mode. All the cards presented from now on will
automatically updated in the panel and may be used to open the door.
If there are not more cards to program, after two minutes the panel will exit program mode.
There is not possible to deregister cards programmed by this method. Use the FERMAX MEET
MANAGEMENT SOFTWARE for full operational possibilities.
DISARM BY CARD: When an already programmed user card is presented to the reader, and it
has been previously assigned to a monitor, the alarm system of the corresponding apartment
will change to HOME mode.
GUEST CODE: Guest code function can be enabled or disabled. The panel needs to be
connected with a module Ref. 1494 to a third-party Access Control System. See INSTALLATION
section.
WIEGAND Protocol used for Wiegand transmission (BURST or 26 BITS). Enter available
parameter depending on the third-party Access Control System
FACILITY: Enter available parameter depending on the third-party Access Control System.
ACCESS PIN: To enable or disable the activation of the relay for ACCES PIN code.
UP to 8 different PIN codes per panel. PIN length between 4 to 6 digits.