EasyManua.ls Logo

Fetco CBS-2161XTS - Menu Features: Batch Parameters

Fetco CBS-2161XTS
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Go to fetco.com for the latest version of all information 7 P141 REV:002 revised 1/2016 ©December 2015
Menu Features: Batch Parameters
PROGRAM Programming Items Factory set Default Programming Range Notes
Batch 1 LEFT*
Batch Summary
Display Summary
Batch Name
Regular 1(-16)
Choose from list:
Regular1
(Regular 1-16)
-OR- Write: any name
-
Batch Volume
2liters to 3:10 gal
[ 0.50-3.10]
3.00 gal
|_________
[]________|
0.50 3.10
Screen will display in
range and units selected
Brew Time
4:00 or 4:30 mm:ss
[ 2:00-10.00]
4:00 mm:ss
|_____
[]___________|
2:00 10:00
CBS-2161XTS 4:00 min
CBS-2162XTS 4:30 min
Nr Of Pulses
8
8
|_____
[]___________|
1 30
CBS-2160 has default
minimum 2 pulses
Prewet Perc.
0%
0 %
|_
[]_______________|
0 15
Pause after prewet
completes
Prewet Delay.
0%
0:00 mm:ss
|_
[]_______________|
0:00 1:00
This feture appears
ONLY if Prewet >0:00
Bypass Perc.
0%
0 %
|_
[]_______________|
0 40
Drip Delay
2:00 mm:ss
2:00 mm:ss
|_____
[]___________|
1:00 5:00
Default is 2 minutes. Brew
basket remains locked
during drip-out
Batch 2 Left**
**Batch 2-4—Right and Batch2-4—Left may be individually selected-or-entirely deleted
Batch ON/OFF
ON
ON
|_________
[]________|
ON OFF
Batch Summary
Display Summary
Batch Name
Regular 1(-16)
Choose from list:
Regular1
(Regular 1-16)
-OR- Write: any name
Model CBS-2160
Batch Volume
2liters to 3:10 gal
[ 0.50-3.10]
3.00 gal
|_________
[]________|
0.50 3.10
Screen will display in
range and units selected
Brew Time
4:00 or 4:30 mm:ss
[ 2:00-10.00]
4:00 mm:ss
|_____
[]___________|
2:00 10:00
CBS-2161XTS 4:00 min
CBS-2162XTS 4:30 min
Nr Of Pulses
8
8
|_____
[]___________|
1 30
CBS-2160 has default
minimum 2 pulses
Pause after prewet
completes
Prewet Perc.
0%
0 %
|_
[]_______________|
0 15
Prewet Delay.
0%
0:00 mm:ss
|_
[]_______________|
0:00 1:00
This feture appears
ONLY if Prewet >0:00
Bypass Perc.
0%
0 %
|_
[]_______________|
0 40
Batch 3 Left **
(See Batch 2-Left)
Batch 4 Left **
(See Batch 2-Left)
Batch 1 Right *
(See Batch 1-Left)
Batch 2 Right **
(See Batch 2-Left)
Batch 3 Right **
(See Batch 2-Left)
Batch 4 Right **
(See Batch 2-Left)
Batch Copy
Copy From Batch L1 L1-L4;R1-R4
Copy To Batch L1 L1-L4;R1-R4
Copy?
L1
ÆL2?
(example)
NO
|_______________
[]__|
YES NO
*Batch 1 cannot be disabled. (CBS-2101XTS)
*Batch 1&4 cannot be disabled. (CBS-2102XTS); **Batch can be disabled, and removed from display
Batch 1 Right
Batch Name Regular 1
Batch Volume 3.00 gal
Brew Time 4 :00
Number of Pulses 8
Prewet Percent 0 %
Prewet Delay 0:00
Drip Delay 2:00
Touch to return
(Example screen for
Batch Summary
display)