Espresso Coffee Machines Compass MB by fiamma57
In case a probe in the groups malfunctions, the displays shows teh following, indicating the probe in
question:
In all of the above mentioned cases, the alarm disappears when the temperature reaches the
allowed value.
9.3. Temperature probe switched off/ interrupted (AL2)
In case a temperature probe in the steam boiler switches off, looses contact or detects a temperature
around 0ºC for more than 5 seconds, the alarm AL2 is set off. All keys start to blink. The electronic unit
blocks the keyboards and all main functions. The display shows:
In case a probe of the coffee water boiler malfunctions, the display shows the following message,
indicating the probe in question:
In case a group probe malfunctions, the display shows the following message, indicating the probe in
question:
In all of the above mentioned cases, the alarm disappears when the probes are correctly connected
again.