13
ZWAVE SPECIFICATION
Notication Command Class:
The device uses Notication Command Class to report dierent events
to the controller (“Lifeline” group).
Notication
Type
Event Event Parameters
Power
Management
[0x08]
Over-load detected [0x08]
Over-current detected [0x06]
System
[0x09]
System Hardware Failure
[0x03]
Device overheat
[0x01]
Protection CC:
Protection Command Class allows to prevent local or remote control of
the device.
Type of protection State Description
Local 0
Unprotected - The device is not pro-
tected, and may be operated normally
via the user interface.
Local 2
No operation possible – button can
not change relay state, any other func-
tionality is available (menu)
RF (remote) 0
Unprotected - The device accept and
respond to all RF Commands.
RF (remote) 1
No RF control – command class basic
and switch binary are rejected, every
other command class will be handled
Meter Command Class:
Meter Type Scale Rate Type Precision Size
Electric
[0x01]
Electric_kWh
[0x00]
Import
[0x01]
2 4
Electric
[0x01]
Electric_W
[0x02]
Import
[0x01]
1 2