20
SPECIFICATIONS
Power supply:
Rated load
(continuous load):
Rated impulse voltage:
Maximum inrush current:
To be used with G type
sockets:
ICE Protection Class:
Active element:
Pollution Degree:
Radio protocol:
Radio frequency:
Maximum transmit power:
Range:
Operating temperature:
Dimensions (Height x
Width x Depth):
EU Directive compliance:
230V AC, 50/60 Hz
Resistive loads: 13A
Incandescent loads: 8A
Inductive general purpose
(cosφ = 0.75-0.8): 13A
Pilot duty (cosφ < 0.35): 700VA
Motor: 750W
Electronic ballasts: 2.5A
1.5kV
80A (20ms)
BS 1363
Class I
Micro-gap relay switch
2 (home and oce use, indoor only)
Z-Wave (500 series chip)
868.4, 868.42 or 869.8 MHz
EIRP up to -0.5dBm
up to 50m outdoors
up to 40m indoors
(depending on terrain and building
structure)
0–40°C
56 x 56 x 58.5mm
RoHS 2011/65/EU
RED 2014/53/EU
#11: Specications
NOTE
Radio frequency of
individual device
must be same as your
Z-Wave controller.
Check information
on the box or consult
your dealer if you are
not sure.
i