ELECTRICAL RATINGS
Do not exceed the maximum electrical ratings of the WPC-2. A circuit breaker rated at 20Amps
at 120VAC must installed in the breaker panel to connect to the WPC-2 power input. Circuit 1
and Circuit 2 are each rated for use of up to 8Amps @ 120VAC. The Pump Relay is rated at a
maximum of 3HP @ 240VAC.
SINGLE DOUBLE TWIN QUAD GFCB
Thomas & Betts TB TB TBBD TBBQ GFB FP-1C-TB
Cutler-Hammer BR BR BRD BRD GFCB BRFP
Square D HOM HOM HOM T HOM T HOM -GFI HOM FP
Murray MP-T MP-T MH-T MH-T MP-GT LX100FP
Siemens/ITE QPQPQTQTQPFQF-3
Challenger C - A-CT - HAGF #FC-1C
Westinghouse or Bryant BR - BQ - GFCB FP-1
Crouse Hinds M P - TRIPLEX - M P-GF -
GE Regular THOP - - - THOP-GF TQLFP-1
SUITABLE LISTED BREAKERS
CIRCUIT BREAKER
MANUFACTURER FILLER PLATE
120V 240V
AWG AMP LB-IN LB-IN HP HP AMP AMP
14 15 3 5 2 0 1/ 2 1 15 12
12 20 35 20 1 2 20 16
10 30 35 20 1 1/2 3 30 24
8 504025 2 5 4032
6654535- -6044
4854535- - - -
310050-----
2100/12550-----
General
Purpose
Branch
Circuit
Breaker
Rating
General
Purpose
Branch
Circuit
Maximum
Current
Capacity
Wiring Inf ormatio n - Copper Conduct ors Only
Terminal Torque*
Wire Size
75°C min.
Insulation
Supply
Circuit
Breaker
Rating
Line and
Neutral
Main
Lugs
Neutral
and
Ground
Max Motor Load
(Continuous Duty)