abovementioned step c, or
In case there is no reference mass applied to platform, the last
reference mass used will be displayed. Press [M+] to confirm, or
In case of new reference mass value, enter it through numeric
keys and press [M+] to confirm. After a new reference mass is
entered, this scale shows 0% to indicator there is no load applied
to platform,
g. This scale is now ready for percentage calculation.
6.9.1 To Quit Percentage Function
Refer to 6.7.2 on how to quit and back to weighing function.
6.10 ANIMAL WEIGHING FUNCTION
Follow the below steps to enter Animal Weighing Function: -
a. Refer to 6.3 on how to select the desired weight unit,
b. If a container is used, place it onto the platform and press [TARE],
c. Press [FUNC] to shift among various functions until Animal Weighing
Function (Ani) appears,
d. Press [M+] to enter,
e. Display last filter (FLt) value applied. Select the preferred filter value
by pressing [FUNC] or [UNIT] key, 3 filer values are available: -
FLt 1 = Fast
FLt 2 = Normal (For human weighing, select this parameter),
FLt 3 = Slow
f. Display the last weight release variation value (rE) applied. Under the
animal weighing function, this scale will hold a weight result until the
pre-defined weight release variation value is achieved,
g. Select the preferred weight release variation value by pressing [FUNC]
or [UNIT] key. 5 auto release range values are available: -
After quitting, the average piece weight stored will be erased.
To enable animal weighing function, set F11 = ON
Weight reading of Animal weighing function cannot be accumulated.
Animal Weighing function will not operate when weight is less than 20d (or 20d
1
for dual
range).
It is a trade off between motion filtering and accuracy. The faster the filter, the lower the
accuracy; The slower the filter, the higher the accuracy. It is recommended that FLt 3
should be applied first. Should situation require, change to a lower FLt number.