Warnings issued when several consecutive malfunctions occur that lead to an interlocking of the AKAS
with displayed error reports. The interlocking status can be cancelled only by a voltage reset.
Electrical connections - Description / Wiring diagrams
Displaying outputs
Warnings (binary xxxxxx10)
error reports (binary xxxxxx01)
6
6.5
Warning
transferred
decim. byte
error
transferred
decim.byte
operating mode
description
possible text in the display
system
reason for the error
6
6
5
5
no monitoring of the
protective circuit
EDM does not respond
even though the OSSDs
are released
-
If this happens during fast speed: valve position mo-
nitors do not switch in fast speed position or at an in-
terruption in the EDMS circuit.
If this happens during Muting: EDMS and EDMO
are both at + 24 V
-
10
10
18
18
9
9
with additional sa-
fety PLC
(e.g.
FPSC}
17
17
overrun traverse
control
slow speed signal error
slow speed signal error
When switching over from fast speed into slow
speed, at SGO remains+ 24 V
When switching over fast speed into slow speed,
the triggereing of the SGS and the SGO is antiva-
lent instead of equivalent
machine stops at the over-
run traverse cam/ cam
switch does not conduct
-
in the case of "warning": open press completely, in
the case of "error": check cable and cam switch
-
30
86
86
90 / 102
29
85
85
89 / 101
no monitoring of the
protective circuit
106
106
114
126
105
105
with additional sa-
fety PLC
(e.g.
FPSC}
113
125
no complete slow speed
position in the Muting sta-
tus
Problem release of the rear
stoppers
This message is displayed when the stroke is star-
ted in slow speed range or with a slow speed re-
quest SGA = 0 and if there is no complete switch-
over of the slow speed position monitors into slow
speed. Check the SGA line for Short circuit to +24 V
and check also the slow speed position monitors and
their lines.
line short circuiting of one RXOX circuit with another
line
internal error
Problem fast speed -- slow
speed request
if this is displayed again after the voltage reset, a ve-
rification by Fiessler Elektronik is necessary
line short circuiting of the SGA circuit with another li-
ne
fast speed/slow speed
signals are faulty in stop
status
fast speed/slow speed
signals are faulty in stop
status
during operation without safety PLC, both EDMS
and EDMO are at + 24 V at the same time in stop-
ped status.
The triggering of the SGS and the SGO is antiva-
lent instead of equivalent
OSSD- error
short circuit of the the mu-
ting lamp line
line short circuiting of the OSSD circuits with other li-
nes
only possible at the version with external Muting
lamp, otherwise: internal problem
130
142
146
150
129
141
145
149
only AKAS 3P
154
166
170
198
153
165
only AKAS...P
169
197
problem at request for hig-
her switchover point:
Muting lamp should not
light up, release box ben-
ding button
line short circuiting of the HUSP circuit with other li-
nes
short circuit in box bending button or line short circui-
ting of the KAST circuit with other lines
E2 / SP error or lateral die
cover missing
problem at pressing of foot
pedal
The SP signal is active at the beginning of the stroke
but receiver element E2 is free. The lateral die cover
is missing or SP signal is not set to the correct value
line short circuiting of the foot pedal circuits FUO
and FUS with other lines
SP_SGS short-circuit error
Hex switches deadjusted
SP and SGS comes at the same time while
bending flat sheet
Readjust the Hex switches onto the selected opera-
ting mode, then carry out a voltage reset. If the error
repeats itself, a repair by Fiessler Elektronik is ne-
cessary.
invalid Hex switch position
external transmitter signals
are received
Turn HEX switch into a permitted position
The transmitter is triggered although the foot pedal is
released, or a transmitter from another AKASĀ® fo-
cuses the receiver. This must be prevented by ade-
quate constructional measures.
interlocking
without prior
warning
interlocking
without prior
warning
246
201
237
with additional sa-
fety PLC
(e.g.
FPSC}
245
unequal slow speed con-
nections
disable key switch - volta-
ge reset
This error happens only during the operating mode
"for connection to safety PLC" if the signals at the
SGO and the SGS are not exactly the same.
The key switch ot the front reset switch have
been activated when the foot pedal was pressed,
or there is an error within the foot pedal, or the
front reset button does not close.
internal error
If this message is displayed immediately after a vol-
tage reset, there is an EMC problem or an internal
failure of the appliance.
background grey:
other message or
no message, if mo-
nitoring functions
are partially cancel-
led