Electrical connections - Description / Wiring diagrams
Displaying outputs
Status messages, handling
directions for the operator
(binary xxxxxx11)
6
6.5
message
transferred
byte
decimal
description
possible text in the display sy-
stem
no overrun traverse test was
carried out because of slow
speed during overrun traverse
test
interrupted protective circuit
set the switch-over point onto the normally required position,
open the press until the machines reaches its UDC and carry
out a new stoke for overrun taverse measurement
Release all protective grids and Emergency off buttons
no monitoring of the
protective circuit
error within the protective cir-
cuits, re-disable and enable
them
no monitoring of the
protective circuit
error within the protective
grids, re-open and close them
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
open again all protective grids and Emergency off buttons
and close them again so that a possible bad contact is acti-
vated again
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
re-open and close the protective grids so that a possible bad
contact is activated again
no monitoring of the
protective circuit
lateral protective grids are
open
, CLOSE!
no monitoring of the
protective circuit
lateral protective grids are
open, i.e. protection by AKASĀ®
is cancelled, activate RESET
error within lateral grids or
Emergency-OFF-button, open
and close them once more
error within rear grids or Emer-
gency-OFF-button, open and
close them once more
no monitoring of the
protective circuit
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
close all lateral protective grids
Press can close only in slow speed
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
open and close again all lateral protective grids and all Emer-
gency-OFF-buttons so that a possible bad contact is activa-
ted again
open and close again all rear protective grids and all Emer-
gency-OFF-buttons so that a possible bad contact is activa-
ted again
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
re-enable emergency OFF button
no monitoring of the
protective circuit
rear protective grid is open
no monitoring of the
protective circuit
lateral and rear protective grids
are open
no monitoring of the
protective circuit
activate reset button for the re-
ar protective grid
no monitoring of the
protective circuit
open the press after overrun
traverse test
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
close rear protective grid
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
close all protective grids
if this is displayed again after the voltage reset, a verification
by Fiessler Elektronik is necessary
reset must be actvated after the operning and closing of the
protective grids
Press has successfully stopped at the cam during the overrun
traverse test, only when the cam is free again, the OSSDs
can be enabled again The ajustment controll-LEDs are flas-
hing slowly until the press brake is not opened completely.
no monitoring of the
protective circuit
box bending function is selec-
ted
bending of flat sheet metal
interruption of the protective
field
no monitoring of the
protective circuit
activate emergency-OFF-reset
of the grids
AKAS@ provides only indirect protection by permitting the
closing movement only in slow speed
during the closing movement, the foot pedal was released
during the closing movement, the protective field was inter-
rupted
after the opening and closing of a protective grid, a reset
must be carried out
Disable key switch. If the same message remains displayed,
there is a risk of short-circuiting of the normally open foot pe-
dal contact.
background grey:
other message or
no message, if mo-
nitoring functions
are partially cancel-
led
FIESSLER
E L E K T R O N I K
Doku Nr. 1379 Stand 27.1.2017 /Aui