EasyManua.ls Logo

Fiessler AKAS-3PM - I;O signals depending on time, moving distance and movementspeed; AKAS3 P M;F Normal Stroke Analysis

Fiessler AKAS-3PM
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I/O signals depending on time, moving distance and movementspeed
8
FIESSLER
E L E K T R O N I K
AKAS3P M/F
Normal stroke from TDC >11mm above clamping point with max. machine overrun of 5mm
Status Stop
FP
pressed
Fast closing 1.half of
breaking
2.half of
breaking
Bending speed
Safety PLC
OUT
FUO 0/1 1/0 1/0 1/0 1/0 1/0
FUS 0/0 1/1 1/1 1/1 1/1 1/1
SGO 0/X 0/1 0/1 0/1 0/1 1/0
SGS 0/0 0/0 0/0 0/0 0/0 1/1
NC out
SP 0 0 0 1 1 1
Manual
signal OUT
KAST 0 0 0 0 0 0
AKAS OUT
OSSD1 0 0 1 1 1 1
OSSD2 0 0 1 1 1 1
SGA 1 1 1 1 1 1
HUSP 0 0 0 0 0 0
Receivers
E5 inactive active 1 active 1 blanked blanked blanked
E6 inactive active 1 active 1 blanked blanked blanked
E3 inactive active 1 active 1 active 1 active 1 blanked
E4 inactive active 1 active 1 active 1
(for 27ms)
blanked blanked
E1 inactive active 1 active 1 blanked blanked blanked
E2 inactive active 1 blanked active 0 blanked blanked
0/1 = AKAS 3PM = 0 / AKAS 3PF = 1
aktive 1 means receiver is active and has to be free
aktive 0 means receiver is active and has to be interrupted
Speed
10mm/s
>11mm
TDC
8 mm
0 mm
clamping
-x mm
BDC
4mm
0 s min.27ms max.800ms
Stroke
Time
Doku Nr. 1379 Stand 27.1.2017 /Aui