EasyManua.ls Logo

Fiessler AKAS-3PM - Page 44

Fiessler AKAS-3PM
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FIESSLER
E L E K T R O N I K
AKAS3P M/F
Normal stroke from 11mm >=TDC > 8mm above clamping point with max. machine overrun
of 5mm.
Status Stop
FP
pressed
slow closing slow
closing
slow
closing
Bending speed
Safety PLC
OUT
FUO 0/1 1/0 1/0 1/0 1/0 1/0
FUS 0/0 1/1 1/1 1/1 1/1 1/1
SGO 0/X 0/X 1/0 1/0 1/0 1/0
SGS 0 0/0 1/1 1/1 1/1 1/1
NC out
SP 0 0 0 1 1 1
Manual
signal OUT
KAST 0 0 0 0 0 0
AKAS OUT
OSSD1 0 0 1 1 1 1
OSSD2 0 0 1 1 1 1
SGA 1 0 0 0 0 0
HUSP 0 0 0 0 0 0
Receivers
E5 inactive active 1 blanked blanked blanked blanked
E6 inactive active 1 blanked blanked blanked blanked
E3 inactive active 1 blanked blanked blanked blanked
E4 inactive active 1 blanked blanked blanked blanked
E1 inactive active 1 blanked blanked blanked blanked
E2 inactive active 0 blanked blanked blanked blanked
0/1 = AKAS 3PM = 0 / AKAS 3PF = 1
aktive 1 means receiver is active and has to be free
aktive 0 means receiver is active and has to be interrupted
Speed
10mm/s
<11mm
TDC
8 mm 0 mm
clamping
-x mm
BDC
4mm
Stroke
Doku Nr. 1379 Stand 27.1.2017 /Aui
I/O signals depending on time, moving distance and movementspeed
8