FIESSLER
E L E K T R O N I K
AKAS3P M/F
Normal stroke from TDC >= 8mm above clamping point with max. machine overrun of 5mm
Status Stop
FP
pressed
slow
closing
slow
closing
Bending speed
Safety PLC OUT
FUO 0/1 1/0 1/0 1/0 1/0
FUS 0/0 1/1 1/1 1/1 1/1
SGO 0/X 0/X 1/0 1/0 1/0
SGS 0/0 0/X 1/1 1/1 1/1
NC out
SP 1 1 1 1 1
Manual signal OUT
KAST 0 0 0 0 0
AKAS OUT
OSSD1 0 0 1 1 1
OSSD2 0 0 1 1 1
SGA 1 0 0 0 0
HUSP 0 0 0 0 0
Receivers
E5 inactive blanked blanked blanked blanked
E6 inactive blanked blanked blanked blanked
E3 inactive blanked blanked blanked blanked
E4 inactive blanked blanked blanked blanked
E1 inactive blanked blanked blanked blanked
E2 inactive blanked blanked blanked blanked
Speed
10mm/s
8 mm
TDC
0 mm
clamping
-x mm
BDC
4mm
Stroke
Doku Nr. 1379 Stand 27.1.2017 /Aui
I/O signals depending on time, moving distance and movementspeed
8