Highlights important safety warnings (WARNING) and cautions (CAUTION) regarding hazards to persons or equipment.
Details the password-protected menu system access levels (Customer, User, Administrator) for system operation and configuration.
Explains various methods for assigning addresses to field devices to meet project requirements.
Procedure to automatically assign addresses to new devices connected to the SLC by activating the panel's AUTO ADDRESSING function.
Method to automatically assign an address to new devices connected to the panel's signaling line circuit via the DEV ADR function.
Instructions for using a handheld IR remote control to assign addresses to devices via infrared signals after enabling IR communication.
Guide on using a handheld programmer, similar to the panel, to assign addresses to new addressable devices.
Accesses menus for Device, NAC, SLC configuration, Learn function, and Voice operations.
Modifies operational parameters of addressable devices connected to the CyberCat's signaling line circuits (SLC).
Makes basic configuration changes to each device's alarm features using the Alarm Features screen.
Details programming options for sensors (Photo, Ion, Heat, Duct), including zone settings and custom messages.
Explains programming options for control and relay modules, including functions like 'ANY OF 3 ZONES'.
Sets module output to activate based on states from any of three specified zones for module functionality.
Sets module output to activate only when states from all three specified zones are active for module functionality.
Sets module output to activate based on the state broadcast from a specific device loop-address for module functionality.
Requires all priority rows in Row D to be active for module output activation for module functionality.
Configures monitor module functions, NO/NC contacts, custom messages, and zone settings.
Details programming options for pull stations, including default MANual ALARM function and zone settings.
Procedure to remove a device from the system configuration by selecting it and pressing ENTER on the Delete Device screen.
Allows reading, writing, enabling, or disabling a selected device's configuration and status from the panel.
Compares the configuration stored in a specific SLC device with the configuration stored in the control panel for that device.
Programs the panel's two on-board notification appliance circuits (NAC #1 and #2) via the NAC Configuration menu.
Sets operational parameters for NAC circuits, including state, protocol, and silenceable/drill/walktest status.
Configures which zones can activate the panel's on-board NAC circuits using ANY ZONE or MULTI ZONE options.
Initiates the Learn function to identify installed addressable devices and add them to the panel's supervision list.
Identifies only new addressable devices connected to the SLC, adding them to the supervision list with default configurations.
Erases the device supervision list and creates a new one by identifying all addressable devices on the SLC.
Accesses configuration parameters for the panel's 31 possible peripheral devices via the Peripheral Menu.
Modifies basic operating parameters of peripheral devices connected to the panel's RS485 peripheral bus.
Performs LED tests, checksum tests, and checksum calculations for specific peripheral devices like Smoke Control or Annunciators.
Programs amplifier settings, including zone configuration for each speaker circuit and audio message assignments.
Assigns zones to an amplifier, defining which zones it will serve and its address on the peripheral bus.
Assigns audio messages to amplifier panel states and selects speaker circuits for activation based on panel conditions.
Provides access to main functions like Configuration, History, Diagnostics, Password, and Maintenance menus.