fillrite.com
11
INSTALLATION AND OPERATION MANUAL
| 900CD DIGITAL METER
Dimensions:
6.75" (H) x 8.46" (W) x 4.10" (D)
Accuracy: ± 1.25 %
Repeatability:
± 0.25% at calibrated flow rate.
Flow Rate: 6 to 40 GPM
Pressure Rating: 50 psi
Construction: Aluminum
Units of Measure:
ounces, pints, quarts, liters, gallons,
1 special “Unit of Measure” option
Counter: 4 digit resettable counter; (.01 – 9999 units)
Totalizers: 7 digit non-resettable “Master” totalizer, 7-digit resettable secondary
Mounting Options: Can be installed for vertical or horizontal mounting by rotating display accordingly
Approvals: UL / cUL / ATEX Listing (see page 6 for information on specific certifications)
Power Supply: 2 “AA” batteries (Alkaline or approved equivalent; Lithium optional for extended battery life);
optional external power supply on certain models
Expected Battery Life: 2 - 4 years of normal use with standard Alkaline batteries
Operating Temperature Range: -40° to 140°F (-40° to 60°C).
Specific conditions of use:
• The Series 900CD may be used with only Part No. MN1500 or MX1500 cells manufactured by Duracell or Part No.
E91 cells manufactured by Energizer.
• The housing of the Series 900 meters is made of powder coated aluminum. Care must be taken in the end use
to ensure coating does not wear away to expose bare metal or that the device must be used only in applications
where it is protected from friction sparking.
Technical Specifications and Information
Certification Information
The following is a list of standards used to attain certification:
• IEC 60079-0, 7th ed.,
• EC 60079-11, 6th ed.,
• EN IEC 60079-0:2018
• EN 60079-11:2012,
• CAN/CSA C22.2 No. 60079-0:15,
• CAN/CSA C22.2 No. 60079-11:14,
• UL913, 8th ed.,
• UL60079-0, 5th ed.,
• UL 60079-11, 5th ed.,
• CAN/CSA C22.2 No. 157-92. (Rev 2016)