INSTALLATION AND OPERATION MANUAL
| 900CD DIGITAL METER
Meter Chamber Assembly
The Meter Chamber consists of upper and lower
chambers, a nutating disc, and four screws
(Figure 2).
1. To expose the meter chamber assembly
and seal remove the 4 screws.
2. The meter chamber can be
dislodged by removing the
4 screws (see Figure 2).
3. Reassemble by reversing this procedure.
If replacing any components of the meter chamber, the complete assembly must be
replaced due to its precision method of construction. This will assure a proper fit,
and correct operation of the chamber.
NOTICE
Figure 2
When returning a meter for service, it must be triple rinsed and accompanied by a note
stating what chemicals have been pumped through it.
Meters not adhering to these specifications may be refused for service.
NOTICE
Repair
Meters needing repairs should be taken to an authorized repair facility. Meters MUST be triple rinsed before taking
them in for repairs.
Safety Testing Approvals
The Fill-Rite 900CD Series Meters have been tested for compliance to the standards set forth by Underwriters
Laboratories (UL), UL Canada, ATEX, and other testing organizations.
To determine which specific compliances apply to your particular meter, refer to the faceplate for information
and compliance logos (see “Certification Information” on page 11).