3-14 FT-100/CI and FT-170/CI Operation Guide
Document 40275-0913
4. Check the operation of the sensor by waving your hand in
front of it.
3.8.4 Steps: Adjusting the Unslit Flap Sensors
Complete these steps to adjust the unslit flap sensors.
1. Create a good case of the type to be inspected.
Figure 3-9. Adjusting the Unslit Flap Sensor
2. Push the test case through the FT-100/CI or FT-170/CI and
as you push allow the guide rails to guide it.
Note: When you pass your hand in front of the sensor beam,
ensure that the indicator light emitting diode (LED) on the back
of the sensor turns off and on. The sensor beam is working
correctly when the sensor turns on and off.
Note: Ensure that all containers are filled correctly and that
the case is packed and sealed correctly.
No. Description
1 Unslit flap sensors
2 Screws on top of the sensors
that you remove to access the
limits switches
1 2