3
FINES – OPERATING INSTRUCTIONS – ENGLISH version
Prover HTB »HTB16,10-M in HTB16,10-D »
1.0. DANGEROUS ZONES
ATTENTION – RISK OF BURNS
HOT SURFACE OF THE GLASS OF THE DORS AND OF THE FRONT SIDE OF THE PROVER
HOT CHAMBER OF THE PROVER
EXTRA CAUTION REQUIRED WHEN REMOVING THE HOT TRAYS FROM THE PROVER
2.0. TECHNICAL DATA
Model HTB16-M HTB10-M
Management manual regulation manual regulation
Tray capacity 16x dim. 60 x 40 cm 10x dim. 60 x 40 cm
Tray distance 70 mm 70 mm
Outside dim. AxBxC 930 x 800 x 905 mm 930 x 800 x 655 mm
Weight 75 kg 65 kg
Total electrical power 1,2 kW 1,2 kW
Fuses 10 A 10 A
Voltage 230V / 50Hz 230V / 50Hz
Water connection R 3/4” R 3/4”
Water preasure 200 – 500 kPa (2-5 bar) 200 – 500 kPa (2-5 bar)
Temperature max. 85°C max. 85°C
Model HTB16-D HTB10-D
Management digital regulation digital regulation
Tray capacity 16x dim. 60 x 40 cm 10x dim. 60 x 40 cm
Tray distance 70 mm 70 mm
Outside dim. AxBxC 930 x 800 x 905 mm 930 x 800 x 655 mm
Weight 75 kg 65 kg
Total electrical power 2,7 kW 2,7 kW
Fuses 16 A 16 A
Voltage 230V / 50Hz 230V / 50Hz
Water connection R 3/4” R 3/4”
Water preasure 200 – 500 kPa (2-5 bar) 200 – 500 kPa (2-5 bar)
Temperature max. 60°C max. 60°C