– 35 –
Scheduling
SchedulingScheduling
Scheduling
About Scheduling
About SchedulingAbout Scheduling
About Scheduling
The system provides end-user schedules (programmable by master/installer only),
which can control various types of events.
Each schedule causes a defined event to start and stop (when appropriate) at a
specified time.
Schedules can be set to automatically repeat at various intervals.
Schedules can be set for random starting, if desired.
FA168CPS provides up to 16 user schedules; FA148CP provides up to 4 user schedules.
Creating Schedules
Creating SchedulesCreating Schedules
Creating Schedules
Alpha Displays:
1. + [#] + [6] [4]
(Master Code)
1 DISARMED
READY TO ARM
2. Enter a 2-digit schedule number from:
01-16 (FA168CPS) or 01-04 (FA148CP).
Press [] to continue.
ENTER SCHED NO.
00=QUIT 00
3. Enter the desired 2-digit event number from the
following list.
00 = clear the scheduled event
01 = turn a programmed output on or off
ENTER EVENT
CLEAR EVENT 00
(see Using Device Commands section for a list of output device numbers used
in your system)
02 = set a user access schedule for one or more users
(see Security Codes section for an explanation of access groups)
03 = send a “latch-key” report to a pager if the system is not disarmed by a specified
time; message sent is “777-7777.
04 = automatically arm the system in STAY mode at a specified time
05 = automatically arm the system in AWAY mode at a specified time
06 = automatically disarm the system at a specified time
07 = Display the word “REMINDER” at a specified time (if selected, the keypad
beeps every 30 seconds beginning when the word “REMINDER” is first
displayed, and the display alternates with the normal keypad display about
every 4-5 seconds. To stop the beeps and cancel the display once it starts,
simply press any key).
Press [] to continue.
4. For event number “01,” enter the output number
associated with this schedule.
Otherwise, this prompt is skipped.
Press [] to continue to the “Start” prompt shown on
the next page.
RELAY NUMBER