20
8. Salty water after regeneration
A. Injectors or screen plugged
A. Clean or replace injectors and
screen
B. Restricted drain flow control
B. Clean drain line flow control
C. Replace brine valve assembly
D. Brine tank is overfilled
9. Water leaks to drain continuously
A. Foreign material in control valve
A. Remove and inspect piston and
seal kit. Replace as necessary
B. Drive motor stopped during
regeneration cycle
B. Check for obstruction in piston and
seals. Replace drive motor.
Inspect condition of power head
gears
C. Control valve continuously cycling
D. Internal valve seal leak
D. Replace seals and/or piston
10. Control valve continuously cycling
Troubleshooting (continued)