Alarm
System
www.firstechonline.com
|
www
.compustar.com
CM2500
Guide
Copyright 2022 Fi rstech , LLC. “Are you not entertained…?” Page
17
Universal Security Control Module
Install.myfirstech.com
CM2500
Master
Guide
Pin 11 Violet - Dome light supervision output: 250mA (-) output. This wire can be used to energize
a relay that can power the vehicle interior lights when the system is disarmed. The output will
stay active for the selected time based on feature 2-04 option settings, until ignition is on.
Pin 12 Grey/White - Warn away (zone 1) Input (-) PIC3; (-) input: This wire will activate the
security system warn away (3 chirps) if (-)ground (-) is applied while armed. This wire can be
used with an auxiliary sensor. This wire is also programmable for several other input
options listed in special options group 4 using an OP500.
Pin 13 Yellow - AUX 1 Output; 250mA negative (-) output. This AUX will provide a (-) output
based on feature 2-08 option settings, and the activation control can be changed using feature
2-10 option settings. This AUX output can also be activated using Drone Mobile.
Pin 14 Black/White - Instant trigger (zone 2) Input (-) PIC4; (-) input: This wire will trigger the
alarm if (-)ground (-) is applied while armed. This input can be used with an Auxiliary sensor.
This wire is also programmable for several other input options listed in special options
group 4 using an OP500.
Pin 15 Yellow/White - AUX 2 Output; 250mA negative (-) output. This AUX will provide a (-)
output based on feature 2-09 option settings, and the activation control can be changed using
feature 2-11 option settings. This AUX output can also be activated using Drone Mobile.
Pin 16 Violet/Black - Trunk Zone input (-) PIC5: This Input is used to monitor the trunk zone of the
vehicle and will trigger the alarm if (-)(-)ground is applied while the system is armed. This
wire is also programmable for several other input options listed in special options group
4 using an OP500.
Connector 3 (CN3), 6-Pin Lock Accessory port
Note: This connector will still be available for any Firstech lock harness. (FT-DM600 or FT-
DM700)
Pin 1 None (empty) - 12v B+ constant output: available when using a Firstech door lock Module
DM600, DM700
Pin 2 Violet/White - Trunk release 250mA, 800mS negative (-) output: This is an optional output that
will release the trunk. Use CN1, Pin 2 if the vehicle is equipped with a (+) trunk release. System
will unlock doors and disarm alarm prior to trunk release.