SV6 - Trunk release: will activate the relay with each trunk release command.
SV7 - Dome light Supervision: will activate the relay and operate in the same manner as the
dome light supervision output.
SV8 - AUX 1: will activate the relay each time AUX 1 is triggered.
SV9 - AUX 2: will activate the relay each time AUX 2 is triggered.
SV10 - Rearm: will activate the relay each time the system is armed.
SV11 - Disarm: will activate the relay each time the system is disarmed.
Special Options Group 3: This special option group allows you to select the input settings of the
Programmable Input Channel (PIC) wire. i.e., If you want to set PIC #5 (default setting (-) hood
status INPUT) to (N/C) hood pin INPUT, you will need change special option 4 from 0 to number
11 using your OP500 or flashing website.
PIC 1 - Red/White: (-) Door zone INPUT (default setting)
PIC 2 - Gray/Black: (-) Hood zone INPUT (default setting)
PIC 3 - Gray/White: (-) Warn away (zone 1) INPUT (default setting)
PIC 4 - Black/White: (-) Instant trigger (zone 2) INPUT (default setting)
PIC 5 - Violet/Black: (-) Trunk zone INPUT (default setting)
PIC setting value description (SV)
SV 1 - (-) Door zone INPUT: This setting allows any PIC programed with value 1 to be connected
to a (-) negative Door zone, which can be used to monitor door status for security purposes.
If (-)ground is applied to any wire programmed for SV1 the system will consider the door
open. This can be used as a single door or multi door input.
SV 2 - (-) Hood Status INPUT: This setting allows any PIC programmed with value 2 to be
connected to a (-) negative Hood zone, which can be used to monitor Hood status for
security purposes. If (-)ground is applied to any wire programmed with SV2 the system will
consider the Hood open.
SV 3 - (-) Warn Away INPUT: This setting allows any PIC programmed with value 3 to be used as
an Auxiliary sensor prewarn Input. Once Armed the CM will activate the 3 warn away
chirps if (-)ground is applied.
SV 4 - (-) Instant Trigger INPUT: This setting allows any PIC programmed with value 4 to be
used as an Auxiliary Sensor Instant Trigger Input. Once Armed the CM will trigger the
alarm if (-)ground is applied to any wire programmed for SV 4.
SV 5 - (-) Trunk Status INPUT: This setting allows any PIC programmed with value 5 to be used
as a (-) negative Trunk zone, which can be monitored for security purposes. If ground is
applied to any wire programmed for SV5 the system will consider the trunk open. This can
be used as a single trunk or multi rear door input.