Adjusting the Armrest
The armrest may be moved
forward or backward by removing
the single screw and nut, and then
repositioning the 2-piece armrest.
Users with shorter arms may find
the armrest more comfortable in
the forward position. In order to
move the armrest backward, the
plastic plug must be removed from
the aluminum tube.
Armrest Strap
Some users prefer to use the strap
when swinging the detector
vigorously, in order to hold the
detector securely against the arm.
The detector can always be used
without the strap, with no
compromise to detector balance
and stability under most conditions.
Hand-grip
Nut
Screw
Searchcoil
Cable
Cable
Plug
Searchcoil
S-Rod
Armrest
Arm Strap
Velcro
Strap
Middle
Stem
Velcro
Strap
Locking
Collar
Locking
Collar
1/4” Headphone Jack
VOLUME
V-BREAK
NOTCH WIDTH
DISCGND BAL
VOLUME
V-BREAK
NOTCH WIDTH
DISCGND BAL
36
ASSEMBLY
DEVICE SPECIFICATIONS
Mechanical: S-rod with electronics housing on rod, 3-piece breakdown
construction, nonmetallic telescoping lower rod, adjustable position Armrest
Weight: 2 lbs. 12 oz. (1.25 kg) with battery installed
Standard searchcoil: 10 inch (25.4 cm) closed-frame elliptical biaxial,
waterproof
Batteries: Single 9 volt rectangular alkaline
Operating principle: VLF induction balance
Operating frequency: 19.2 kHz, crystal controlled
Reactive overload: 10,000 micro-cgs (with standard searchcoil)
Resistive overload: 1,200 micro-cgs (with standard searchcoil)
Ground balance range: From ferrite to salt water inclusive
Discrimination ground suppression: Combination of 2
nd
and 3
rd
order methods
Target-ID ground suppression: 3
rd
order
Battery life: 15+ hours on good quality alkaline (less using backlight)
Operating temp range: 14 to 122 degrees F (-10 to +50 C)
Operating humidity range: 0 - 90% noncondensing
Immediately after powering on, your detector's unique 10-digit serial
number is displayed once on the LCD. Two digits are displayed at a
time; five 2-digit numbers are displayed in sequence. This 10-digit
serial number is the same serial number imprinted on the label inside
the battery compartment and on the box.
TREASURE HUNTER’S CODE OF ETHICS
• Always check Federal, State, County and local laws before searching.
• Respect private property and do not enter private property without the
owner’s permission.
• Take care to refill all holes and leave no damage.
• Remove and dispose of any and all trash and litter found.
• Appreciate and protect our inheritance of natural resources, wildlife and
private property.
Act as an ambassador for the hobby; use thoughtfulness, consideration and
courtesy at all times.
• Never destroy historical or archaeological treasures.
• All treasure hunters may be judged by the example you set; always conduct
yourself with courtesy and consideration of others.
5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fisher F19 and is the answer not in the manual?

Fisher F19 Specifications

General IconGeneral
Operating Frequency19 kHz
Battery Life20-25 hours
Water ResistanceSearchcoil is waterproof
Searchcoil10" elliptical concentric
Batteries1 x 9V
DiscriminationAdjustable
DisplayLCD
Target ID Range0-99
SensitivityAdjustable
Search ModesAll Metal, Discrimination
Ground BalanceAutomatic and Manual
Target IDYes
Audio Outputheadphone jack
Audio Tones4 tones