44
13、Appendix
Air conditioner nominal working condition and working range:
Test condition Indoor side Outdoor side
DB(℃) WB(℃) DB(℃) WB(℃)
Nominal cooling 27 19 35 24
Nominal heating 20 -- 7 6
Rated cooling 32 23 43 26
Min. temp. for cooling 21 15 18(-15) --
Rated heating 27 -- 24 18
Min. temp. for heating 20 -- -7 -8
Note:
1. The design of this unit conforms to the requirements of EN14511 standard.
2. The air volume is measured at the relevant standard external static pressure.
3. Cooling (heating) capacity stated above is measured under nominal working conditions corresponding
to standard external static pressure. The parameters are subject to change with the improvement of
products, in which case the values on nameplate shall prevail.
4. In this table, the outdoor side 18(-15) DB (℃) temperature of low-ambient cooling include two values,
the one in the bracket is the working condition of the appliance with function of low-ambient cooling .
18 is the working condition for the unit without low ambient cooling fuction. -15 is the working condition
for the unit with low ambient cooling function.
WARNING!
z This appliance is not intended for use by persons (including children) with reduced physical sensory
or capabilities, or leak of experience and knowledge, unless they have been given supervision on
instruction concerning use of appliance by a person responsible for their safety.
z Children should be supervised to ensure that they do not play with the appliance.