DC50 Digital Dispenser Operating Manual
© 2020 Fisnar - 12 - DC50 Rev 02
DISPENSE SETUP
Fill the syringe barrel (with syringe barrel tip cap fitted on the syringe barrel) with the fluid material
to be dispensed. Once filled, correctly insert piston into syringe barrel. Attach syringe barrel to
syringe barrel adapter head as shown below. See FIG. 6.
Do not overfill the syringe barrel and/or lay the syringe barrel on its side. This
will prevent fluids from flowing back into the machine – refer to figures A & B
below.
1.
Connect the syringe barrel adapter air tube to the “Air Out” port on the front of the
machine. (4) See FIG. 5. Can be standard use with Fisnar adapter head assemblies
supplied with green color push to connect fitting (5606038).
2.
If the syringe barrel adapter to be used with the machine has a bayonet fitting attached to
the end of it, make sure to cut the bayonet fitting off from the hose. Use adapter
5779K712 push to connect air fitting (1/4” stem x 5/32” tube O.D.) with the air-line when
installing the hose into the air out fitting in the front of the machine.
FIG. 6: Dispense Setup
A
B
C