7
Safety measures, integrated
The heating section has an integrated magnetic contact to cut power to the heating ele-
ments if the heating section is removed from the top panel. The electronic control system is
fitted with an acoustic alarm that will activate when temperatures exceeding 200°C are regis-
tered.
Safety functions
The heating section has an integrated safety thermostat that will cut power to the heating
elements if temperatures exceed 230°C. The thermostat can be reset and connected once
the temperature has fallen. To reset the thermostat, press the red button next to the heating
section. The electronic control system has a fuse to protect the control system against over-
load. The fuse is located under the front panel with the display.
We recommend that the fryer is serviced to find out why the safety thermostat was trig-
gered.
Who may use the appliance
This appliance is not intended for use by children! Neither should it be used by persons with re-
duced physical or mental capacity, or who lack appropriate experience and knowledge unless they
have been trained or instructed in the use of the appliance by someone with responsibility for
their safety.