Model 5600 & 5600 Fleck Econominder®
Service Manual
Model 5600 & 5600 Econominder®
Model 5600 Econominder Installation and Start-up Procedures
NOTE: Install the water softener with the inlet, outlet and drain connections made according to
manufacturer’s recommendations and to meet applicable plumbing codes.

Other manuals for Fleck 5600 Econominder

Questions and Answers

  • C
    Christopher BrownJul 27, 2025
    Why does the water from my Fleck 5600 Econominder Control Unit not feel soft?
    • R
      Robert SmithJul 27, 2025
      Check the salt level in the brine tank of your Fleck Control Unit, and ensure that the salt level is maintained above the water level. If the issue persists, it is recommended to contact your local water service technician.
  • M
    Monica MartinAug 12, 2025
    What to do if there is a power outage with my Fleck 5600 Econominder?
    • J
      Jeffrey FowlerAug 12, 2025
      In the event of a power outage, reset the Time of Day on your Fleck Control Unit. Consult the “Setting the Time of Day” page for instructions.

Summary

Fleck 5600 Econominder Service Manual Overview

Fleck 5600 Econominder Installation and Start-up

Guides on initial setup and installation of the water softener.

Manual Operation and Programming

Setting Water Usage Program

Details how to set time, hardness, and people for automatic regeneration.

Control Valve Drive Assembly and Parts

Meter Assembly and Service Procedures

Troubleshooting Guide

Troubleshooting: Operation and Water Quality

Addresses common problems like regeneration failures, hard water, and salt usage.

Troubleshooting: Flow, Pressure, Control Valve Issues

Covers issues with water pressure, flow control, drain lines, and timer/valve malfunctions.

Troubleshooting: Filter and Meter Control

Discusses filter backwashing, iron bleeding, and meter measurement problems.

Fleck 5600 Econominder Specifications

General IconGeneral
Service Capacity48, 000 grains
Regeneration CycleAdjustable
MountingTop Mount
Operating Pressure20 - 125 psi
Regeneration TypeMeter Initiated
Power Supply120V AC
Valve Size1"
Brine Draw Flow Rate0.5 GPM
MaterialsNoryl
Operating Temperature34 - 110°F