7700 VALVE
table of CONTENTS:
1 VALVE SPECIFICATION P. 2
2 VALVE INSTALLATION P. 3
3 INSTALLATION INSTRUCTIONS P. 4
4 VALVE OPERATION P. 5
5 TROUBLESHOOTING P. 7
8P Vanne 7700 ANG 8/03/05 19:20 Page 1

Other manuals for Fleck 7700

Questions and Answers

  • R
    Rachel WeberAug 17, 2025
    Why is my Fleck 7700 Control Unit softener delivering hard water?
    • A
      Andrea HughesAug 17, 2025
      If your Fleck Control Unit softener delivers hard water, you can try the following: close the by-pass valve; add salt to the brine tank, maintaining the salt level above the water level; replace or clean the injector and screen; check the brine tank fill time, cleaning the brine flow control if it’s blocked; ensure the distributor tube is not cracked and check the O’ ring and tube pilot; remove the obstruction from meter; check the meter connection to the timer and the meter cap; check the programming and reset as needed; repeated flushing of the hot water tank may be required; replace seals and spacers and/or piston.
  • T
    Timothy JonesAug 20, 2025
    What to do if Fleck Control Unit softener fails to regenerate?
    • T
      Tamara MillerAug 20, 2025
      If your Fleck Control Unit softener fails to regenerate, assure permanent electrical service by checking the fuse, pull chain, or switch. You may also need to replace the timer, check the meter connection to the timer and the meter cover, clean or replace the meter, replace the drive motor, or check the programming and reset as needed.
  • B
    Benjamin WardAug 22, 2025
    Why does my Fleck Control Unit use too much salt?
    • A
      Andrew LeblancAug 22, 2025
      If your Fleck Control Unit uses too much salt, check the salt usage and salt setting. Also, check the programming and reset as needed. Please, see problem n°7.
  • F
    fbrownAug 26, 2025
    How to fix loss of water pressure in Fleck 7700 Control Unit?
    • C
      ccherryAug 26, 2025
      To fix a loss of water pressure in your Fleck Control Unit, clean the line to the softener, clean the valve and resin bed, or remove the piston and clean the valve.
  • K
    Kara Landry MDAug 28, 2025
    What to do if my Fleck 7700 Control Unit has salted water in service line?
    • E
      eyoungAug 28, 2025
      If you notice salted water in the service line of your Fleck Control Unit, clean the injector and replace the screen. You may also need to replace the timer, clean or replace the brine valve, clean the brine line flow control, raise the water pressure to at least 1,4 bar, or check the programming and reset as needed.
  • C
    Christian SmithAug 31, 2025
    Why is there excessive water in brine tank of Fleck 7700?
    • C
      calebmeyerAug 31, 2025
      If there's excessive water in the brine tank of your Fleck Control Unit, try cleaning the drain line flow control (DLFC), replacing the brine valve, or checking the programming and resetting as needed.
  • N
    normadavisSep 2, 2025
    How to resolve iron in softened water with Fleck Control Unit?
    • A
      Anita OrtizSep 3, 2025
      To resolve iron in softened water when using a Fleck Control Unit, check backwash, brine draw and brine tank refill. You might need to increase the frequency of regeneration or increase backwash time. Contact the dealer.
  • J
    justinodomSep 5, 2025
    What causes loss of resin through drain line in Fleck Control Unit?
    • D
      david68Sep 5, 2025
      Loss of resin through the drain line in your Fleck Control Unit could be due to several factors. Try adding or replacing the top distributor, ensure the presence of an air check system in the brine tank, and make sure the drain line flow control is sized correctly.
  • A
    Aaron RichardsonSep 8, 2025
    Why Fleck Control Unit softener fails to draw brine?
    • C
      Christopher LeeSep 8, 2025
      If your Fleck Control Unit softener fails to draw brine, you can try the following: Clean drain line flow control (DLFC), clean injector and replace screen, clean filter, increase water pressure to 1,4 bar at least, change seals and spacers and/or piston assembly, check the programming and reset as needed, or replace timer.
  • T
    Timothy SerranoSep 12, 2025
    What causes the Fleck 7700 valve to cycle continuously?
    • D
      Diane BurchSep 12, 2025
      If the valve cycles continuously on your Fleck Control Unit, it may be necessary to replace the timer or the circuit board. You might also need to replace the cycle cam or reinstall it.

Summary

Valve Installation

Water Pressure Requirements

Minimum and maximum water pressure requirements for effective valve operation.

Installation Instructions

General Installation Steps

Covers site selection, plumbing, tube preparation, lubrication, and initial flushing.

Connecting and Purging

Instructions for connecting power, purging air from the unit, and initial valve cycle.

Valve Operation

Manual Regeneration

Procedures for initiating regeneration manually via button presses.

Programming Mode

Information and caution regarding the valve's programming mode.

7700 Valve Programming

Regeneration Type Selection

Select regeneration trigger: time clock, metered immediate, or metered delayed.

System Capacity Input

Input system capacity in Kilo grain (US) or m³x°tH (metrical).

Water Hardness Input

Set water hardness in grain (US) or metrical format (french degrees).

Regeneration Time Setting

Set the specific time of day for automatic regeneration, e.g., 2 A.M.

Fleck 7700 Specifications