7700 VALVE PROGRAMMING
1-10
7700 VALVE
8. Cycle times based on dF
8.1. Backwash:
I.e.: 10 minutes [1-10]
2-60
8.2. Brine draw & slow rinse
l.e.: 60 minutes [2-60]
3--5
8.3. Second backwash
l.e.: 5 minutes [3--5]
4-10
8.4. Fast rinse
I.e.: 10 minutes [4-10]
5--12
8.5. Brine fill
I.e.: 12 minutes [5-12]
F21.6
9. Flow meter size (F)
I.e.: - 1-1/4’’ turbine meter (US) [F-78]
- 1-1/4’’ turbine meter (metrical) [F21.6]
cF25
10. Security coefficient (cF)
I.e.: - security coefficient 25% [cF25]
- no security coefficient [cF-0]
LF50
11. Electrical mains frequency
I.e.: - frequency 60 Hz [LF60]
- frequency 50 Hz [LF50]
Press once on button to save modified parameters
and return in service mode.
Note: Valve calculates programming changes [CALC]
and return to the service mode/Time of day.
C
Rev.1
1. Press once the button
to go from one display mode
to another.
2.
Set parameters values by
using the and buttons.
3. Depending on the
programmation, some
displays will not appear and
some will not be variable.
4. Bold characters default
setting.