LEVEL DESCRIPTION
Regeneration cycles
The settings 8-1 to 8-6 enable the regulation of the regeneration cycle times.
The amount of cycles is established by the piston type. (View stage 2).
I.e.:
Cycle 1-8 mn [1--8]
Cycle 2-65 mn [2-65]
Cycle 3-4 mn [3--4]
DF dFFF FLtr
1) Backwash 1) Brine refill 1) Backwash
2) Brine draw/Slow rinse 2) Pause (salt saturation) 2) Fast rinse
3) 2
nd
backwash 3) Backwash
4) Fast rinse 4) Brine draw/Slow rinse
5) Brine refill 5) 2
nd
backwash
6) Fast rinse
Meter size
Not visualized in time clock mode: [7--1]
This setting is identified by the letter F. It allows to regulate the amount of pulses generated by the meter per litre.
The meter used with this valve is a 1-1/4’’ [F21.6]
Security factor
Not visualized in time clock mode: [7--1]
This setting is identified by the letters cF. It allows a security margin by lowering the available capacity.
The setting is a percentage.
I.e. :
- No security factor [cF 0]
- Security factor 35%: the available capacity is reduced by 35% [cF35]
Mains frequency
This setting is identified by the letters LF. It allows regulating the mains frequency.
If the frequency is set correctly, the timer display will remain accurate.
- 60 Hz (default setting with the following display U- - 1) [LF60]
- 50 Hz (default setting with the following display U- - 2) [LF50]
Notice:
If the regeneration way setting changes during the programmation, the valve will go round fully in order to reinitialize.
If the system capacity, hardness or security factor settings have just been modified during the programmation, the card will
recalculate the system capacity and take one third of the total capacity as a new value for the reserve capacity.
Error display
The codes only appear in service mode.
There are 3 possibles errors:
Error code
Err0
Err1
Err2
Cause
The motor is blocked
The motor runs continuously
The valve hasn’t regenerated for 99 days.
Remedy
Unplug the unit from the mains,
Once plugged back, the error code
disappears.
If the error cause isn’t solved, the code will
reappear. Do not attempt to solve the
problem. Change the card or motor.
A regeneration has to be done for the valve
to run normally.
Reset
Press simultaneously the buttons and for 25 seconds or until the day time displayed is 12 :00. The program will then take
its default settings.
The valve will have to be fully reprogrammed following the indications in the previous chapters.
Notice: if a reset has occurred, the valve will turn round fully to recover its initial position.