EasyManuals Logo

Fleck 7700 User Manual

Fleck 7700
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
2 - VALVE INSTALLATION
3
7700 VALVE
Water pressure
A minimum of 1,4 bar of water pressure is required for the regeneration valve to operate effectively.
Do not exceed 8,5 bar ; if you face this case, you should install a pressure regulator upstream the system.
Electrical connection
An uninterrupted current supply is required. Please make sure that your voltage supply is compatible with your
unit before installation. If the electrical cable is damaged, it must imperatively be replaced by a qualified personal.
Existing plumbing
Existing plumbing should be in a good shape and free from limescale.
The installation of a pre filter is always advised.
By-pass
Always provide a by pass valve for the installation, if the unit is not equipped with one.
Water temperature
Water temperature is not to exceed 43°C, and the unit cannot be subjected to freezing conditions.
Presentation
2.1
2.2
2.3
2.4
2.5
2.6
Service indicator:
- Valve in service : L.E.D on
- Night regeneration:
flashing L.E.D.
Flow indicator:
L.E.D. flashes proportionally
to flow.
Programmation indicator:
- valve in programmation :
L.E.D on.
Not used
in metrical mode.
Regeneration button Value setting buttons.
8P Vanne 7700 ANG 8/03/05 19:33 Page 3

Other manuals for Fleck 7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fleck 7700 and is the answer not in the manual?

Fleck 7700 Specifications

General IconGeneral
BrandFleck
Model7700
CategoryControl Unit
LanguageEnglish

Related product manuals