Page #6 background image
Start a manual regeneration
There are 2 options to initiate regeneration.
A) Press and release the button.
If an immediate regeneration is programmed, the valve will immediately start regeneration.
With a delayed regeneration, the service L.E.D. will begin to flash immediately and the regeneration will occur at
the preset regeneration time.
B) Press and hold for 5 seconds the button.
In any case the valve will go into regeneration immediately.
Advance to the next regeneration cycle
To advance to the next regeneration cycle, press the button.
This will have no effect if the valve is already advancing to the next cycle.
PROGRAMMING
CAUTION: The programming has to be done only by the installer for the setting of the valve parameters. The
modification of one of these parameters could prevent the good functioning of the device.
To enter the program mode, the valve has to be in service. While in program mode, the valve will continue to
operate normally monitoring all information. The programming is stored in permanent memory with or without line
or battery backup power.
To enter programming mode, press simultaneously the and for 5 seconds.
Press on the button in order to jump to the next stage.
Use the and buttons in order to modify the displayed values.
Note: You must pass through all the programming steps and come back in service position to save the
modifications that have been done during the programming mode.
4 - VALVE OPERATION
7700 VALVE
6
4.3
4.2.2
4.2.3
4.4
Water hardness °tH
For example: 25 °tH
(Not viewed in time clock version)
Regeneration time
For example: 2 A.M.
(only visualised in delayed metered and timeclock mode)
Day override (maximum days between 2 regenerations)
For Example : regeneration every 4 days
(only visualised in timeclock mode, setting is imperative.)
VALVE OPERATION DURING A POWER FAILURE
During a power failure, all the data will be saved and restored once the line power is restored. The data can be
saved for many years with no loss. The electronics will be inoperative and all regeneration will be delayed. The
electronics will restore all the information to the time where the power failure occurred. The valve does not record
the amount of water used during a power cut.
If the valve is in delayed metered regeneration, the reserve capacity will be set to a third of the full capacity.
8P Vanne 7700 ANG 8/03/05 19:21 Page 6

Other manuals for Fleck 7700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fleck 7700 and is the answer not in the manual?

Fleck 7700 Specifications

General IconGeneral
BrandFleck
Model7700
CategoryControl Unit
LanguageEnglish

Related product manuals