Do you have a question about the Fleck 7000SXT and is the answer not in the manual?
Procedure to set the current time of day on the control unit's display.
How to schedule a regeneration cycle to occur at a later time.
Method to initiate a regeneration cycle on demand.
Regenerates based on water usage as soon as system capacity is depleted.
Regenerates at a programmed time after system capacity is depleted.
Regenerates on a timed interval at a programmed regeneration time.
Regenerates on a weekly schedule based on user-defined days.
Explains display information and user interaction during a regeneration cycle.
Details how the control operates while in programming mode.
Step-by-step guide to manually start a regeneration cycle.
Describes the unit's behavior and memory retention during power outages.
Procedure to set the current time of day within the programming mode.
Steps to access the master programming interface.
Procedure to save settings and return to normal operation.
Instructions for performing soft and master resets of the unit.
Setting the unit of measure and time display format.
Specifies the type of regeneration cycle the valve follows.
Determines how the control triggers a regeneration cycle.
Configuration for single or dual tank water softener systems.
Selection of which tank is active in a two-tank system.
Sets the treatment capacity of the system media in grains.
Input for the hardness level of the incoming water supply.
Choice between percentage safety factor or fixed reserve capacity.
Sets the percentage of system capacity reserved for regeneration.
Sets a fixed volume reserve capacity for the system.
Sets the maximum number of days between regeneration cycles.
Specifies the time of day for regeneration initiation.
Adjusts the duration for each step of the regeneration cycle.
Schedules regeneration for specific days of the week.
Sets the current day of the week for day-of-week controls.
Identifies the type of flow meter connected to the control.
Configures the meter constant for non-standard flow meters.
Guide to setting day override, regeneration time, and feedwater hardness.
Steps to view flow rate, peak flow, hours in service, volume used, and software version.
Detailed list of parts for the valve assembly, including DLFC options.
Explanation of error codes and their corresponding reset and recovery procedures.
Diagram showing water flow path when the unit is in normal service.
Diagram illustrating water flow during the backwash regeneration cycle.
Diagram showing water flow path during the brine draw cycle.
Diagram illustrating water flow during the slow rinse regeneration cycle.
Diagram showing water flow path during the rapid rinse regeneration cycle.
Diagram illustrating water flow during the brine tank refill process.
| Brand | Fleck |
|---|---|
| Model | 7000SXT |
| Category | Controller |
| Language | English |