To configure hard drive warnings:
1. From the Main Menu, click
and then click Event > Warning > HDD.
2. Under Event Type, select the hard drive event you would like to configure.
No HDD: No hard drive detected.
Disk Error: A hard drive error has been detected.
Disk Full: The hard drive is full or almost full. You can enter the percentage of disk
space remaining that will trigger a warning under Less Than (e.g. when less than
10% of the hard drive is empty, trigger a warning). Disk Full warnings will not occur if
overwrite is enabled.
All: Configure warnings for all hard drive events.
3. Configure the responses the system will take when the selected event occurs:
Show Message: Show a popup message on the monitor.
Send Email: Check to enable email alerts. Enabling Send Email requires you to
set up email notifications. See13.3.5 Configuring Email Alerts, page 70) for full
instructions.
Buzzer: Check to activate the system buzzer.
4. Click OK to save changes.
13.3.12 Configuring Network Warnings
Network warnings will notify you if your system loses connection to the Internet or local
network or if there is an issue on your network.