FLIR Lepton 1.6 - Figure 5 - State Diagram Showing Transitions Among the Five Power States

FLIR Lepton 1.6
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FLIR LEPTON® Engineering Datasheet
The information contained herein does not contain technology as defined by the EAR, 15 CFR 772, is publicly available,
and therefore, not subject to EAR. NSR (6/14/2018).
Information on this page is subject to change without notice.
Lepton Engineering Datasheet, Document Number: 500-0659-00-09 Rev: 203
16
Figure 5 - State Diagram Showing Transitions among the Five Power States
The power states are listed here:
Off: When no voltage is applied, Lepton is in the off state. In the off state, no camera
functions are
available.
Uninitialized: In the uninitialized state, all voltage forms are applied, but Lepton has not yet
been
booted and is in an indeterminate state. It is not recommended to leave Lepton in this state
as power is
not optimized; it should instead be booted to the on-state (and then transitioned
back to Shutdown if
imaging is not required).
On: In the on state, all functions and interfaces are fully available.