Temperature in Kelvin x 100
Window
Reflected
Temperature
Temperature in Kelvin x 100
0 = High, 1 = Low, 2 = Auto
In Auto mode, 0 = High, 1 = Low
0 = current gain mode is desired, 1 = gain mode
switch desired
Temperature
Gain Mode
Threshold High to
Low (°C)
Temperature threshold in °C used to determine
when an Auto switch to Low gain mode (while in
High gain mode) should occur in Radiometry
enabled/TLinear disabled mode
Temperature
Gain Mode
Threshold Low to
High (°C)
Temperature threshold in °C used to determine
when an Auto switch to High gain mode (while in
Low gain mode) should occur in Radiometry
enabled/TLinear disabled mode
Temperature
Gain Mode
Threshold High to
Low (K)
Temperature threshold in Kelvin used to
determine when an Auto switch to Low gain mode
(while in High gain mode) should occur in TLinear
mode
See Gain States, page 21.