EasyManua.ls Logo

FLIR T420 - Setting up Above, Below, and Interval Alarms

FLIR T420
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Working with color alarms and isotherms18
Color alarm
Image
Interval alarm
Condensation alarm
Insulation alarm
18.2 Setting up above, below, and interval alarms
Follow this procedure:
1. Push the joystick to display the menu system.
2. Use the joystick to go to
(Color).
3. Push the joystick to display a submenu. Use the joystick to select the type of alarm:
(Above alarm)
(Below alarm)
(Interval alarm)
4. Push the joystick. The threshold temperature is displayed at the bottom of the screen.
#T559879; r. AO/35410/35410; en-US
54