TROUBLESHOOTING CHART
CONVERSION TABLE
Symptom Possible Cause(s) Corrective Action
Pump will not prime or retain Air leak in suction line Repair or replace
prime after operating Defective check valve Replace
Upper housing leaking Tighten bolts
Suction lift too high Lower pump
Debris in check valve(s) Clean check valve(s)
Pump runs but no fluid Faulty suction piping Repair or replace
Defective check valve Replace
Suction lift too high Lower pump
Clogged inlet Clean or replace
Inlet line valve closed Open valve
Motor runs too hot Voltage incorrect Check voltage
Insufficient ventilation for motor Insure proper ventilation
Flow rate is low Piping or hose is damaged Clean or replace
Clogged check valve Clear obstruction
Worn check valve Replace
Voltage incorrect Check voltage
Tank over pressurized Check tank pressure
Pump leaks Upper housing loose Tighten screws
Pistons loose Tighten pistons
Pump head loose on motor Tighten pump head
Switch loose Tighten switch
Defective Diaphragm Replace
Pump will not run No electricity Check connections, fuse, breakers
Defective pressure switch Replace switch
Motor has open circuit Replace
Thermal protector has cut off Allow motor to cool 15-30 min
TO CONVERT TO
MULTIPLY BY
Gallons, U.S. Liters 3.785
Liters Gallons, U.S. 0.264
Pounds/Sq. Inch Bar 0.069
Bar Pounds/Sq. Inch 14.5
Fahrenheit Celsius (°F-32) .556
Celsius Fahrenheit (°C X 1.8) + 32