EasyManua.ls Logo

FLOJET 4305-144 User Manual

FLOJET 4305-144
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
3.25
(82)
3.5
(90)
3.44
(87)
FEATURES
Self-Priming
Dry Running
Soft, Noise Absorbing Mounts
Corrosion Resistant Materials
•D.C. Models Meet U.S.C.G. Electric Standards
•A.C. Models Have 6’ Power Cord
SPECIFICATIONS
Motor: Permanent Magnet, Ball Bearing. CE Models
are fully suppressed.
Pump: Four chamber diaphragm design; Self-priming
up to 10 ft. suction lift; Pump able to run dry
without damage; Removable port to hose
connectors.
Note: 4300 Series pumps are not bypass type
pumps and can be used in systems with an
accumulator tank.
(Available on 12 & 24V d.c. Models and 230V a.c. Model)
With pump switch off, and battery fully charged, fill water
tank, open all faucets then turn pump switch on. Water
will begin to flow. When water is free of air, turn faucets
off, remember you are filling the water heater and the
toilet and shower lines. When all valves are shut off
pump will stop. Should pump fail to stop, turn switch off
and see the trouble shooting guide..
OPERATION
Pump Series Dimensions - Inches (mm) Weight
Height Width Length lb. (kg)
4305-xxx 3.75 (95) 6.3 (160) 8.2 (208) 3.9(1.8)
4305-144 3.75 (95) 6.3 (160) 8.6 (218) 4.5(2.1)
4325-XXX 3.75 (95) 6.3 (160) 9.9 (252) 6.0(2.8)
AMP DRAW FLOW PRESSURE SWITCH
MODEL* VOLTS @ 10 psi (0.7 bar) GPM (V.in) MAX psi (bar)
4305-144 12V dc 5.0 3.5 (13.5) 40 (2.8)
4305-500 12V dc 4.0 3.3 (12.5) 35 (2.5)
4305-501 24V dc 1.8 3.3 (12.5) 35 (2.5)
4305-502** 24V dc 2.0 2.3 (8.7) 20 (1.3)
4305-503** 12V dc 2.4 2.3 (8.7) 20 (1.3)
4325-143 12V dc 6.0 4.5 (17) 40 (2.8)
4325-343 24V dc 2.5 4.5 (17) 40 (2.8)
4325-443 32V dc 2.0 4.5 (17) 40 (2.8)
4325-043 115V ac 0.5 4.5 (17) 40 (2.8)
4325-243 230V ac 0.3 4.5 (17) 40 (2.8)
**Low Flow/Low Pressure Models
* CE fully suppressed models are identified by a prefix “R” and a CE mark on the label. (i.e. R4305-500)
Self Declaration Of Conformance (SDOC) is available upon request.
Model 4300 Series
“Quad II Diaphragm”
Models4305 & 4325
Automatic Water System Pump
Question and Answer IconNeed help?

Do you have a question about the FLOJET 4305-144 and is the answer not in the manual?

FLOJET 4305-144 Specifications

General IconGeneral
BrandFLOJET
Model4305-144
CategoryWater Pump
LanguageEnglish

Summary

Operation

Installation

DC Wiring

Troubleshooting

Disassembly Guide

Detailed steps for taking the pump apart for service and repair.

Pressure Switch Disassembly

Instructions for removing and disconnecting the pressure switch.

Upper Housing Disassembly

Steps to remove and inspect the upper housing and check valve.

Lower Housing, Diaphragm, Motor Disassembly

Procedure for separating the lower housing from the motor shaft.

Diaphragm and Motor Component Removal

Guide for detaching diaphragm and motor components.

Reassembly Guide

Procedures for reassembling pump components after service.

Motor and Diaphragm Reassembly

Steps to correctly reassemble motor and diaphragm sections.

Upper Housing and Check Valve Reassembly

Instructions for putting back the upper housing and check valve.

Pressure Switch Reassembly

Guide for reinstalling the pressure switch.

Service Parts

Accessories

Quick Connect Port System

Overview of available quick connect fittings for pump ports.

Strainers

Details on compatible strainer part numbers and specifications.

Warranty and Return Procedure

Related product manuals