EasyManua.ls Logo

FLOJET N5000 - User Manual

FLOJET N5000
2 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Model N5000
CO
2
Operated Bag-in-Box Pump
Model N5000
CO
2
Operated Bag-in-Box Pump
OUT IN
PRODUCT
IN
OUTGAS
TO VENT CO2
DISCHARGE
INSTALL HOSE
TO GAS OUT
20 ICON, FOOTHILL RANCH, CA
CO2 OR DRY COMPRESSED AIR OPERATED
MODEL : N5000-130
OPERATING PRESSURE 20 TO 80 PSI
6 3/16
(157)
2 7/16
(157)
2 1/4
(57)
2 11/16
(57)
5 13/16
(57)
2
(51)
Automatic
Shutoff Valve
Product
Out
Gas
Out
Gas
In
Product
In
INSTALLATION
MOUNTING
Pump should be located within 10 ft. (3.0 m) of bag-in-
box and must be mounted with ports facing down. May
be mounted above or below bag. Fasten mounting
brackets securely to rack or mounting board. The pump
is sanitized at factory and needs no further sanitizing
before connection to the product supply.
HOSE CONNECTIONS
Product “IN”, use 3/8” (7.9 mm) I.D. x 1/8” (3.1 mm) wall
vinyl or Tygon hose, food grade or equivalent. Secure
with OETIKER 17.0 706R clamp or worm gear clamp
with 360° uniform clamping band. Avoid sharp bends
that could restrict flow or cause hose to collapse under
vacuum. Connect to bag-in-box connector (or transfer
valve if used) and clamp both ends.
Product “OUT”, use reinforced 1/2” (12.7 mm), 3/8” (9.5
mm) or 1/4” (6.3 mm) I.D. hose for discharge. Connect to
product “OUT” port and dispensing head product
(syrup) connection and clamp both ends securely.
Gas “IN”, make sure CO
2
regulator is set at zero. Use
reinforced 1/4” (6.3 mm) hose, connect gas “IN” to gas
supply fitting on regulator. If pumps are installed in an
enclosed area such as a basement, it is recommended
to connect a hose to the gas discharge port and vent
CO
2
to atmosphere.
OPERATION
To start operation, regulate gas pressure to desired
setting. For most installations, 65 PSI (4.5 BAR) will be
adequate. Open dispensing valve to purge air from
system. Pump will now operate automatically by starting
and stopping on demand, as beverages are served and
maintaining constant pressure at the dispensing valve.
Product flow and pressure can be adjusted by
increasing or decreasing gas pressure to accommodate
varying product viscosities, length of lines or other
installation conditions. CAUTION: Do not exceed 80
PSI (5.6 BAR) gas pressure.
The Flojet Model N5000 has an auto shutoff valve which
stops the pump by shutting off the gas supply when the
bag is empty and high vacuum builds up in the inlet line.
The control will automatically restart the pump when a
new bag is connected and vacuum in the inlet line has
returned to normal.
DIMENSIONS Inches (mm)
PRODUCT DATA
Pump Design ........Positive Displacement, Double Diaphragm
Power Source ......................................CO
2
Gas, Nitrogen or
Compressed Filtered Air
Materials of Construction (wetted parts) ........Celcon M90,
Santoprene
®
, EPDM, 302 or 304 Stainless Steel Spring
Temperature Limits ..........................34° - 120°F (1.1°- 49°C)
Weight ........................................................1.22 lbs. (0.55 kg.)
Dimensions ........................5-3/8” H x 6-7/32” W x 2-7/16” D
(135.7 mm x 157.9 mm x 61.9 mm)
Displacement ................................................2.5 oz. per cycle
Self Priming ............................................Up to 10 ft. (3.05 m)
Operating Pressure ..............................20 psi (1.4 bar) min. /
80 psi (5.5 bar) max.
Liquid Inlet Pressure ............................10 psi (0.7 bar) max.
Flow Rate ........................4.0 oz. (118.3 ml)/sec. - Open Flow
Approvals ................................................NSF listed, SK & CE
Auto Shutoff Valve....
Automatically shuts off pump when product
supply is depleted and restarts when connected to new supply.
AVAILABLE PORT FITTINGS
Gas Inlet:
1/4” (6.3mm) Barb, plastic, straight
1/4” (6.3mm) Barb, brass w/CO
2
shut-off - straight,
tee or elbow.
John Guest for 1/4” O.D. tubing, plastic or brass
w/CO
2
shut-off
Gas Outlet:
1/4” (6.3mm) Barb, plastic, straight
Product Inlet & Outlet:
1/4” (6.3mm) Barb, stainless steel, straight or elbow
3/8” (9.5mm) Barb, plastic, straight
3/8” (9.5mm) Barb, stainless steel, straight or elbow
1/2” (12.7mm) Barb, stainless steel, straight
John Guest for 1/4” or 3/8” O.D. tubing, plastic
Question and Answer IconNeed help?

Do you have a question about the FLOJET N5000 and is the answer not in the manual?

Summary

Available Port Fittings

Gas Inlet Fittings

Lists barb and John Guest fittings for gas connections, including CO2 shut-off options.

Gas Outlet Fittings

Lists barb fittings available for gas outlets.

Product Inlet & Outlet Fittings

Lists barb and John Guest fittings for product connections, in various materials and sizes.

Installation Guide

Mounting Instructions

Details on how and where to mount the pump, including location and orientation.

Hose Connections

Instructions for connecting product and gas hoses to the pump.

Pump Operation

Troubleshooting Guide

Pump Does Not Operate

Addresses issues where the pump fails to start when the dispensing valve is opened.

Pump Operates But No Flow

Covers scenarios where the pump runs but no product is dispensed.

Pump Continues to Operate After Product Sold Out

Deals with the pump running after the product source is empty.

Low Pressure at Dispensing Valve

Explains causes for reduced pressure at the dispenser.

Pump Fails to Restart Automatically

Addresses issues with the pump not resuming operation after a new bag.

Pump Fails to Stop When Dispensing Valve Closed

Covers situations where the pump continues to run when idle.

Warranty Information

Return Procedure

FLOJET N5000 Specifications

General IconGeneral
BrandFLOJET
ModelN5000
CategoryWater Pump
LanguageEnglish

Related product manuals