Describes the motor type as permanent magnet, ball bearing, with CE models being fully suppressed.
Details the pump's four-chamber diaphragm design, self-priming capability, and dry-running feature.
Clarifies that 4300 Series pumps are not bypass type and can be used with an accumulator tank.
Instructions on filling the water tank and turning the pump switch on for initial water flow.
Explains that the pump stops when all valves are shut off, and what to do if it fails to stop.
Guidance on installing pump ports, mounting, and connecting hoses for optimal performance.
Details on wire gauge, switch usage, and fuse protection for DC powered pumps.
Addresses problems like failure to prime, pump not turning on, or pulsating flow.
Step-by-step instructions for taking apart the pump's pressure switch, upper housing, and lower housing.
Procedures for reassembling the pump's motor, diaphragm, upper housing, and pressure switch.
Lists part numbers for various pump components across different models.
Details quick connect port systems and strainers compatible with pump series.
Outlines the two-year limited warranty covering defects in material and workmanship.
Instructions for returning products, including obtaining an authorization number.