OWNER’S MANUAL
Submersible Sump Pumps
NOTICE D’UTILISATION
Pompes submersibles
pour puisard
MANUAL DEL USUARIO
Bombas sumergibles
para sumideros
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 1-800-365-6832
English .........................Pages 2-9
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le 1 (800) 365-6832
Français ...................Pages 10-17
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español .................Páginas 18-25
© 2011 FP894 (6/22/2011)
E100ELT
293 Wright Street, Delavan, WI 53115
Phone: 1-800-365-6832
Fax: 1-800-526-3757
Web Site: FlotecWater.com

Questions and Answers

  • C
    curtisgregoryAug 12, 2025
    How to troubleshoot a Flotec Water Pump that won't start?
    • D
      Darryl HarrisAug 12, 2025
      If your Flotec Water Pump won't start or run, first ensure it's properly plugged into an outlet. If it still doesn't work, check the fuse and replace it with the correct size if it's blown. In case of low voltage, inspect the wiring. If issues persist, the motor or float switch might be defective and require replacement. A clogged impeller can also prevent the pump from starting; unplug the pump, remove the lower body, and clear any blockage. If the impeller is damaged, replace it. Finally, try wiping the switch with a clean cloth.
  • M
    matthewreedAug 18, 2025
    What to do if my Flotec Water Pump delivers little or no water?
    • N
      natalie25Aug 19, 2025
      If your Flotec Water Pump operates but delivers little or no water, start by checking the line voltage; if it's below 110 volts, inspect the wiring. Should the wiring be adequate, contact your power company. Debris caught in the impeller or a restricted intake screen can also cause this issue; remove the pump and clean these components. Inspect the impeller for wear or damage; clean it if plugged, replace if necessary, or replace the pump. Ensure the check valve has a 1/8” (3mm) hole drilled between the pump discharge and the check valve, 1-2” above the pump discharge and below the waterline. Also, verify that the check valve is correctly installed with the flow arrow pointing away from the pump.
  • S
    Susan CoxAug 27, 2025
    Why won't my Flotec Water Pump shut off?
    • J
      Jamie WrightAug 27, 2025
      If your Flotec Water Pump won’t shut off, the switch may be defective. Try wiping the switch and checking its functionality before replacing it. A restricted discharge due to an obstacle or ice in the piping can also cause this; unplug the pump, remove it from the sump, and clean the pump and piping. Additionally, a restricted intake screen can be the culprit; unplug the pump, remove it from the sump, and clean the intake screen and impeller.
  • J
    Jeffrey MartinSep 3, 2025
    Why does my Flotec E100ELT start and stop frequently?
    • J
      Jeffrey SimmonsSep 4, 2025
      If your Flotec Water Pump starts and stops too often, it might be due to backflow of water from the piping. Consider installing or replacing the check valve. Another possible cause is a faulty switch, which would require replacement.

Flotec E100ELT Specifications

General IconGeneral
Horsepower1/2 HP
Voltage115 V
Phase1
Max Head25 ft
Discharge Size1-1/2 in
Pump TypeSubmersible
Thermal ProtectionYes
Motor TypePSC