OWNER’S MANUAL
Convertible Deep Well Jet Pumps
NOTICE D’UTILISATION
Pompe à éjecteur transformables
pour puits profonds
MANUAL DEL USUARIO
Bombas Convertibles tipo “Jet”
para Pozos Profundos
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-800-365-6832
English . . . . . . . . . . . . . . Pages 2-16
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français . . . . . . . . . . . Pages 17-31
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español . . . . . . . . . . .Paginas 32-47
®
2760 0197
FP313 (Rev. 4/9/09)
Series FP4200
®
1543 0195
Series FP4300
®
P.O. Box 342, Delavan, WI 53115
Phone:
1-800-365-6832
Fax:
1-800-526-3757
E-Mail:
info@flotecwater.com
Web Site:
http://www.flotecwater.com

Questions and Answers

  • D
    Dennis CampbellAug 17, 2025
    What to do if my Flotec FP4200 Water Pump does not deliver water to full capacity?
    • J
      Jenny LarsonAug 17, 2025
      If your Flotec Water Pump isn't delivering water to its full capacity, the water level in the well might be lower than estimated, potentially requiring a new nozzle and venturi combination. If steel piping is used, corrosion or liming could be causing excess friction; consider replacing it with plastic pipe or new steel pipe. Also, ensure the piping isn't too small, as using larger piping could resolve the issue.
  • S
    Stephanie JohnsonAug 20, 2025
    What to do if my Flotec FP4200 Water Pump motor will not run?
    • A
      Adam IrwinAug 20, 2025
      If your Flotec Water Pump motor isn't running, first ensure the disconnect switch is on. Then, check the fuse and replace it if blown, or reset the circuit breaker if it has tripped. Also, examine the wires at the motor to ensure they are correctly connected and tightened. Finally, the pressure switch contacts might be dirty, in which case you should disconnect the power and file the contacts with an emery board or nail file.
  • A
    Anthony ParkerAug 25, 2025
    What to do if my Flotec FP4200 motor runs hot and overload kicks off?
    • J
      Jason SmithAug 26, 2025
      If the motor of your Flotec Water Pump runs hot and the overload kicks off, it could be due to incorrect wiring. Refer to the wiring instructions. Also, low voltage could be the cause, so check with your power company. Finally, if the pump cycles too frequently, consider installing heavier wiring if the current wire size is too small (refer to the Electrical/Wiring Chart).
  • C
    Chelsea KingAug 27, 2025
    What to do if my Flotec FP4200 Water Pump motor runs but no water is delivered?
    • R
      Robin WilsonAug 27, 2025
      If the motor of your Flotec Water Pump runs but no water is delivered, consider these possibilities: * If it's a new installation, the pump may not have picked up prime. Re-prime it according to the instructions. * The pump may have lost prime; check all connections on the suction line and shaft seal. * The foot valve or strainer could be plugged, requiring cleaning. * The ejector or impeller might be plugged; clean them as necessary. * A check valve or foot valve could be stuck shut, in which case, replace it. * Pipes might be frozen; thaw them. * The foot valve and/or strainer could be buried in sand or mud; raise them above the bottom of the water source. * The water level may be too low for a shallow well setup; if it exceeds 25’ (7.6M), a deep well pump is needed.
  • D
    Derrick WilkinsonAug 29, 2025
    Why does my Flotec Water Pump have air spurts from faucets?
    • B
      belindasmallAug 30, 2025
      If you're experiencing air spurts from the faucets connected to your Flotec Water Pump, it could be due to several reasons. The pump might be in the process of picking up prime; once it does, it should pump solid water without air. There could also be a leak on the suction side of the pump; check the joints for leaks using soapy water. Another possibility is that the well is gaseous; in this case, consult the factory about installing a sleeve in the well. Lastly, it could be due to intermittent over-pumping of the well, where the water is drawn down below the foot valve; if possible, lower the foot valve or restrict the pump discharge.
  • T
    Thomas CarterSep 1, 2025
    Why does my Flotec FP4200 not deliver water to full capacity?
    • R
      Ruth NelsonSep 1, 2025
      If your Flotec Water Pump isn't delivering water to its full capacity, the water level in the well might be lower than estimated, potentially requiring a new nozzle and venturi combination. If you're using steel piping, it could be corroded or limed, causing excess friction; replace it with plastic pipe where possible, or with new steel pipe. Also, the piping might be too small in size, so consider using larger piping.
  • D
    David SingletonSep 4, 2025
    How to troubleshoot a Flotec Water Pump motor that will not run?
    • C
      crystalmendezSep 4, 2025
      If your Flotec Water Pump motor isn't running, start by checking if the disconnect switch is turned on. Then, inspect the fuse and replace it if it's blown, or reset the circuit breaker if it's tripped. If these steps don't resolve the issue, the starting switch might be defective and needs replacement after you DISCONNECT POWER. Also, examine the wires at the motor for looseness, disconnections, or incorrect wiring referring to wiring instructions. Remember to DISCONNECT POWER before checking and tightening any wiring to avoid electric shock.
  • J
    juanballardSep 12, 2025
    Why does my Flotec FP4200 Water Pump motor run hot and the overload kicks off?
    • B
      Bradley JohnsonSep 12, 2025
      If your Flotec Water Pump motor runs hot and the overload protection activates, it could be due to several reasons. First, refer to the wiring instructions to ensure the motor is wired correctly. Also, check the supplied voltage to ensure it is not too low. Contact your power company and install heavier wiring if the wire size is too small. Finally, if the pump cycles too frequently, refer to the section on too frequent cycling.
  • D
    Dr. Victoria SanchezSep 14, 2025
    Why am I getting air spurts from the faucets when using my Flotec FP4200 Water Pump?
    • A
      Arthur MichaelSep 14, 2025
      If you're experiencing air spurts from faucets when using your Flotec Water Pump, it could be due to the pump picking up prime; once the pump has picked up prime, it should pump solid water without air. Another cause could be a leak in the suction side of the pump, where the suction pipe is sucking in air. Check the joints for leaks using shaving cream. If the well is gaseous, consult the factory about installing a sleeve in the well. Lastly, intermittent over-pumping of the well, where the water is drawn down below the foot valve, can cause air spurts; lower the foot valve if possible, otherwise restrict the pump discharge.
  • D
    Dominique PaulNov 21, 2025
    Why does my Flotec FP4200 deliver water but not shut off or pump cycles too frequently?
    • A
      Andrew RoblesNov 21, 2025
      If your Flotec Water Pump delivers water but doesn't shut off or cycles too frequently, there are several potential causes. * The pressure switch may be out of adjustment or its contacts might be welded together. Disconnect the power and adjust or replace the pressure switch. * Faucets might have been left open, so ensure they are closed. * The venturi, nozzle, or impeller could be clogged, requiring cleaning. * A standard pressure tank might be waterlogged, lacking an air cushion; drain the tank to the air volume control port. * Pipes or foot valves could be leaking, necessitating a check of all connections for air leaks and replacement of the foot valve if needed. * The air charge in a pre-charged tank might be too low. Check the air pressure using a tire pressure gauge at ...

Summary

Safety Instructions

General Safety Guidelines

Covers general warnings, cautions, and advice for safe pump operation and maintenance.

Electrical Safety Precautions

Focuses on electrical hazards, including capacitor voltage and proper grounding.

Warranty Information

Replacing an Existing Pump

Deep Well Pump Replacement Steps

Provides step-by-step instructions for removing and replacing a deep well pump.

Shallow Well Pump Replacement Steps

Provides step-by-step instructions for removing and replacing a shallow well pump.

Shallow Well Pump Installation Guide

Well Point Installation Procedure

Details for installing pumps for shallow wells using well points.

Cased Well Installation Procedure

Details for installing pumps for shallow wells in cased wells.

Surface Water Pump Installation Guide

Deep Well Pump Installation Guide

4 or Larger Deep Well Setup

Instructions for installing deep well pumps in 4" or larger wells.

2 Deep Well Setup

Instructions for installing deep well pumps in 2" wells.

Discharge and Pressure Tank Connections

Pre-Charge Tank Connection Steps

Details for connecting the pump discharge to a pre-charged pressure tank.

Standard Tank Connection Steps

Details for connecting the pump discharge to a standard pressure tank.

Electrical Setup and Wiring

Motor Switch Settings and Voltage Selection

Covers motor voltage changes and settings for different power supplies.

Voltage Selector Type Instructions

Specific instructions for plug-type and dial-type voltage selectors.

Wiring Chart and Procedures

Wiring Connections and Safety Guidelines

General wiring safety, connection steps, and code compliance.

Recommended Wire and Fuse Sizes

Chart detailing wire sizes and fuse ratings based on motor HP and distance.

Deep Well Pump Startup Procedure

Shallow Well Pump Startup Procedure

Troubleshooting Common Pump Issues

Repair Parts Identification

Ejector Package Details

Shallow Well Ejector Kit Parts

Information and part numbers for shallow well ejector kits.

Deep Well Ejector Kit Parts

Flotec FP4200 Series Specifications

General IconGeneral
BrandFlotec
ModelFP4200 Series
CategoryWater Pump
LanguageEnglish

Related product manuals