EasyManua.ls Logo

Flotec FPSC1725X - User Manual

Flotec FPSC1725X
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installation/Operation/Parts
For further operating,
installation, or maintenance
assistance:
Call 1-800-365-6832
English .................... Pages 2-12
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le
1 (800) 365-6832
Français ............... Pages 13-24
Instalación/Operación/Piezas
Para mayor información sobre
el funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-365-6832
Español ...............Paginas 25-36
FP874 (10/29/09)
®
OWNER’S MANUAL
4" Submersible Pumps
Two and Three Wire, 1/2 thru 1
1
2 HP, 60 Hz
U.S. Patent 5,133,639
NOTICE D’UTILISATION
Pompe submersible de 4 po
à deux et trois fils, de 1/2 à 1
1
2 ch, 60 Hz
de brevet U.S. 5,133,639
MANUAL DEL USUARIO
Bombas sumergibles de 4"
de dos y tres hilos, 1/2 a 1
1
2 CV, 60 Hz
Patente de EE.UU. No. 5,133,639
®
P.O. Box 342, Delavan, WI 53115
Phone:
1-800-365-6832
Fax:
1-800-526-3757
E-Mail:
info@flotecwater.com
Web Site:
http://www.flotecwater.com

Questions and Answers

  • B
    Brandon PowellAug 7, 2025
    How to fix a Flotec Water Pump that starts and stops?
    • N
      Nathaniel JenkinsAug 7, 2025
      The motor may be overheating. This can happen if the discharge or intake are obstructed or if the pump is in water that is too shallow. Check these potential causes and correct them.
  • S
    Samantha BakerAug 12, 2025
    What to do if my Flotec Water Pump won't start or run?
    • W
      William WalkerAug 12, 2025
      If your Flotec Water Pump won't start or run, here are a few things to check: * First, ensure the pump is properly plugged into a working outlet. * Next, inspect the fuse or breaker. If it's blown, replace the fuse with one of the correct size or reset the breaker. * Also, low line voltage can be a factor. If the voltage is below the recommended minimum, examine the wiring size from the main switch. If the wiring is adequate, contact your power company or hydro authority. * If none of these steps work, the motor may be defective, requiring pump replacement.
  • T
    tarabutlerAug 20, 2025
    What to do if my Flotec FPSC1725X Water Pump delivers little or no water?
    • Z
      Zachary SilvaAug 20, 2025
      Several issues could be the cause. There might be a restricted discharge due to an obstacle or ice in the piping, in which case you should remove the pump and clean both the pump and the piping. Alternatively, there could be a restricted intake; remove the pump and clean out the intake screen. Low line voltage can also cause this problem; check the wiring size from the main switch on your property. If the wiring is okay, contact your power company or hydro authority. A worn or plugged impeller can also be the culprit, requiring you to replace the pump. Finally, the anti-airlock hole might be plugged. In that case, turn off the pump, clean out the anti-airlock hole, and then restart the pump.
  • G
    gharperAug 25, 2025
    Why won’t my Flotec Water Pump start?
    • T
      Timothy IrwinAug 25, 2025
      First, check if the pump is properly plugged into an outlet. If the fuse is blown, replace it with a fuse of the correct size, or reset the breaker. If the voltage is below the recommended minimum, inspect the wiring size from the main switch on your property. If the wiring is adequate, contact your power company or hydro authority. As a last resort, you might need to replace the pump.
  • D
    Dustin MorganAug 29, 2025
    What to do if Flotec FPSC1725X Water Pump discharge from faucets is air or milky?
    • A
      amandahernandezAug 29, 2025
      If the water discharging from your faucets appears milky or contains air when using a Flotec Water Pump, it could be due to gas present in the well water. To address this, remove the bleeder orifices and plug the tees, ensuring that these plugs are completely sealed to prevent leaks. Another potential cause is a malfunctioning air volume control. If this is the case, replace the control as needed.
  • A
    Andrew RobertsNov 14, 2025
    Why does my Flotec FPSC1725X operate but delivers little or no water?
    • M
      Maria HartNov 15, 2025
      If your Flotec Water Pump is running but not delivering enough water, consider these possibilities: * There might be a restriction in the discharge, such as an obstacle or ice in the piping. In this case, remove the pump and clean both the pump and the piping. * A restricted intake can also cause this problem. Remove the pump and clean out the intake screen. * Low line voltage could be the issue. If the voltage is under the recommended minimum, check the wiring size from the main switch on your property. If the wiring is okay, contact your power company or hydro authority. * A worn or plugged impeller can also reduce water delivery, requiring pump replacement. * Finally, a plugged anti-airlock hole might be the cause. Turn off the pump, clean out the anti-airlock hole, and then ...
  • K
    Kelly GregoryDec 3, 2025
    Why is my Flotec FPSC1725X Water Pump delivering little or no water?

    Flotec FPSC1725X Specifications

    General IconGeneral
    Voltage115V
    MaterialThermoplastic
    PhaseSingle-phase
    Housing MaterialThermoplastic
    Impeller MaterialThermoplastic
    TypeSubmersible
    Horsepower0.25 HP
    Maximum Head25 ft
    Max Head Pressure25 ft
    Pump TypeSubmersible
    Discharge Size1-1/4 inch NPT
    Outlet Size1-1/4 inch NPT

    Related product manuals